| 数据搜索系统,热门电子元器件搜索 |
|
TZ4ST-R2C 数据表(PDF) 15 Page - Autonics Corporation |
|
|
|||||||||||||||||||||||||||||
TZ4ST-R2C 数据表(HTML) 15 Page - Autonics Corporation |
|
15 / 16 page ![]() H-86 TZN/TZ Series Communication output Calculation range of Block Check Character Start Code Header Code END Code BCC Code Address Code Text STX 101 100 R/W X/D ETX FSC Supply system power ※A → Over min. 4sec, B → Within max. 300ms, C → Over min. 20ms A B C TZ/TZN S T X A D R C M D T X T E T X B C C S T X A D R C M D T X T E T X B C C A C K S T X A D R C M D T X T E T X B C C Master Interface Standard EIA RS485 Number of connections Max. 31units. It is available to set address 01 to 99. Communication method 2 wire half duplex Synchronous method Asynchronous type Communication distance Within 1.2km Communication speed 2400, 4800, 9600(available to set) Start bit 1bit(Fixed) Stop bit 1bit(Fixed) Parity bit None Data bit 8bit(Fixed) Protocol BCC Upper Terminating resistance N 1 (N-1) TZ/TZN TZ/TZN TZ/TZN (A+) (A+) (A+) (B-) (B-) (B-) RX(-) TX(+) System ordering ※Use a proper twist pair for communication. Communication control ordering 1. The communication control ordering of TZ/TZN Series is exclusive protocol. 2. After 4sec. being supplied the power into master system, then able to start communicating. 3. Initial communication will be started by master system. When Command signal comes out from master system then TZ/TZN Series will respond. Communication Command and Block Format of Command and Response ① Start code It indicates the first of Block STX → [02H], in case of response, ACK will be added. ② Address code This code is master system can discern TZ/TZN Series and able to set within range of 01 to 99.(BCD ASCII) ③ Header code: It indicates command as 2 alphabets as below. RX(Read request) → R[52H], X[58H] RD(Read response) → R[52H], D[44H] WX(Write request) → W[57H], R[58H] WD(Write response) → W[57H], D[44H] ④ Text: It indicates the detail contents of Command/ Response. (see command) ⑤ END code: It indicates the end of Block. ETX → [03H] ⑥ BCC: It indicates XOR operating value from the first to ETX of the protocol as abbreviation of TZ/TZN. Communication Command ● Read [RX] of measurement/setting value : Address 01, Command RX 1.Command (Master) ① Command STX 0 1 R X P 0 ETX FSC Start Address Command head P:Process value S:Setting value End BCC ② Application: Address(01), Header code(RX), Process value(P) STX 0 1 R X P 0 ETX FSC 02 30 31 52 58 50 30 03 BCC ● Write [WX] of setting value: Address 01, Command WX 1.Command(Master) ① Command STX 0 1 W X S 0 Symbol 103 102 101 100 ETX FSC Start Address Command head S:Setting value Space/- 10 3 102 101 100 End BCC ② Application: In case of writing Address(01), Heading Coad(WX), Setting value(S) +123. STX 0 1 W X S 0 Symbol 103 102 101 100 ETX FSC 02 30 31 57 58 53 30 20 30 31 32 33 03 BCC Response ● Read of process/Setting value 1. In case of receiving normal process value : The data is transmitted adding ACK[60H]. (In case process value is +123.4) A C K S T X 0 1 R D P 0 Symbol 103 102 101 100 Decimal point E T X F S C N U L L A C K S T X 0 1 R D P 0 Space 1 2 3 4 1 E T X B C C N U L L 06 02 30 31 52 44 50 30 20 31 32 33 34 31 03 B C C 00 2. In case process value is -100 A C K S T X 0 1 R D P 0 - 0 1 0 0 0 E T X B C C N U L L 06 02 30 31 52 44 50 30 2D 30 31 30 30 30 03 B C C 00 ※It is responded with 1 byte sized NULL(00H) at the end of response frame (next BCC 16). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |