| 数据搜索系统,热门电子元器件搜索 |
|
UC-30GM-R2 数据表(PDF) 4 Page - Pepperl+Fuchs Inc. |
|
|
|||||||||||||||||||||||||||||
UC-30GM-R2 数据表(HTML) 4 Page - Pepperl+Fuchs Inc. |
|
4 / 5 page ![]() Ultrasonic sensor UC2000-30GM-IUR2-V15 4 Germany: +49 621 776 4411 Pepperl+Fuchs Group Refer to “General Notes Relating to Pepperl+Fuchs Product Information”. USA: +1 330 486 0001 Singapore: +65 6779 9091 www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com # Synchronization This sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate using internally generated clock pulses. It can be synchronized by applying an external square wave. The pulse duration must be ≥ 100 µs. Each falling edge of the synchronization pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for ≥ 1 second, the sensor will revert to normal operating mode. Normal operating mode can also be activated by opening the signal connection to the synchronization input (see note below). If the synchronization input goes to a high level for > 1 second, the sensor will switch to standby mode, indicated by the green LED. In this mode, the outputs will remain in the last valid output state. Note: If the option for synchronization is not used, the synchronization input has to be connected to ground (0 V) or the sensor must be operated via a V1 cordset (4-pin). The synchronization function cannot be activated during programming mode and vice versa. The following synchronization modes are possible: 1. Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs. In this case, each sensor alternately transmits ultrasonic pulses in a self multiplexing mode. No two sensors will transmit pulses at the same time (see note below). 2. Multiple sensors can be controlled by the same external synchronization signal. In this mode the sensors are triggered in parallel and are syn- chronized by a common external synchronization pulse. 3. A separate synchronization pulse can be sent to each individual sensor. In this mode the sensors operate in external multiplex mode (see note below). 4. A high level (+UB) on the synchronization input switches the sensor to standby mode. Note: Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the multiplex- ing of the ultrasonic transmit and receive signal and the resulting increase in the measurement cycle time. Note on communication with the UC-30GM-R2 interface cable The UC-30GM-R2 interface cable allows for communication with the ultrasonic sensor using ULTRA3000 software. The cable creates a connection between a PC RS-232 interface and the programming plug socket on the sensor. When connecting to the sensor, make certain the plug is lined up correctly; otherwise no communication will be possible. The key of the cable’s plug must be aligned to the groove of the socket on the sensor (not with the arrow symbol on the sen- sor). Programmable parameters with the ULTRA3000 software • Evaluation limits A1 and A2 •Operation mode • Sonic speed • Temperature offset (The inherent temperature-rise of the sensor can be considered in the temperature compensation) • Expansion of the unusable area (for suppression of unusable area echoes) • Reduction of the detection range (for suppression of remote range echoes) • Time of measuring cycle • Acoustic power (interference of the burst duration) • Sensitivity • Behavior of the sensor in case of echo loss • Behavior of the sensor in case of a fault • Average formation via an allowed number of measuring cycles • Selection of the parameter set, RS 232 or manually Note: When connected to a PC and running the ULTRA3000 software, the sensor can act as a long term data logger as well. Green LED Red LED Yellow LED A1 Yellow LED A2 During Normal Operation - Temperature compensated - with removed programming plug Interference (e.g. compressed air) On Off Off Off On Flashing Object in evaluation range Object in evaluation range remains in previous state Object in sensing range Object in sensing range remains in previous state During Sensor Programming Evaluation limit A1: Object detected No object detected Evaluation limit A2: Object detected No object detected Operation mode: Rising slope mode Falling slope mode Zero line mode Flashing Off Flashing Off On On On Off Flashing Off Flashing Off Off Off Flashing Flashing Off Off Off Flashing Flashing Off Off Flashing Flashing Flashing Off Flashing Standby Flashing Off remains in previous state remains in previous state A1 A2 E2 E3 LED yellow Dual-LED green/red LED yellow Evaluation limit 1 "Power on"/Disturbance Evaluation limit 2 1 2 4 3 LED-window V15-plug connector (M12x1) 1: TXD 2: RXD 3: not used 4: GND Temperature/program connector (PC connection via inter- face cable UC-30GM-R2) Groove |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |