| 数据搜索系统,热门电子元器件搜索 |
|
TLV5619CPWR 数据表(PDF) 4 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLV5619CPWR 数据表(HTML) 4 Page - Texas Instruments |
|
4 / 27 page ![]() www.ti.com ELECTRICAL CHARACTERISTICS TLV5619 SLAS172F – DECEMBER 1997 – REVISED FEBRUARY 2004 over recommended operating free-air temperature range, sdupply voltages, and reference voltages (unless otherwise noted) STATIC DAC SPECIFICATIONS PARAMETER TEST CONDITIONS MIN TYP MAX UNIT Resolution Vref(REFIN) = 2.048 V at 5 V, 1.024 V at 3 V 12 bits Vref(REFIN) = 2.048 V at 5 V, Integral nonlinearity (INL) See (1) ±1.5 ±4 LSB 1.024 V at 3 V, Vref(REFIN) = 2.048 V at 5 V, Differential nonlinearity (DNL) See (2) ±0.4 ±1 LSB 1.024 V at 3 V, Vref(REFIN) = 2.048 V at 5 V, EZS Zero-scale error (offset error at zero scale) See (3) ±3 ±20 mV 1.024 V at 3 V, Vref(REFIN) = 2.048 V at 5 V, Zero-scale-error temperature coefficient See (4) 3 ppm/ °C 1.024 V at 3 V, Vref(REFIN) = 2.048 V at 5 V, % of FS EG Gain error See (5) ±0.25 ±0.5 1.024 V at 3 V, voltage Vref(REFIN) = 2.048 V at 5 V, Gain error temperature coefficient See (6) 1 ppm/ °C 1.024 V at 3 V, Zero scale 65 PSRR Power-supply rejection ratio See (7) and (8) dB Gain 65 (1) The relative accuracy or integral nonlinearity (INL), sometimes referred to as linearity error, is the maximum deviation of the output from the line between zero and full scale excluding the effects of zero code and full-scale errors. (2) The differential nonlinearity (DNL), sometimes referred to as differential error, is the difference between the measured and ideal 1 LSB amplitude change of any two adjacent codes. Monotonic means the output voltage changes in the same direction (or remains constant) as a change in the digital input code. (3) Zero-scale error is the deviation from zero voltage output when the digital input code is zero. (4) Zero-scale-error temperature coefficient is given by: EZS TC = [EZS (Tmax) - EZS (Tmin)]/Vref× 10 6/(T max - Tmin). (5) Gain error is the deviation from the ideal output (2 × V ref - 1 LSB) with an output load of 10 kΩ excluding the effects of the zero-error. (6) Gain temperature coefficient is given by: EG TC = [EG(Tmax) - EG (Tmin)]/Vref× 10 6/(T max - Tmin). (7) Zero-scale-error rejection ratio (EZS-RR) is measured by varying the VDD from 4.5 V to 5.5 V dc and measuring the proportion of this signal imposed on the zero-code output voltage. (8) Gain-error rejection ratio (EG-RR) is measured by varying the VDD from 4.5 V to 5.5 V dc and measuring the proportion of this signal imposed on the full-scale output voltage after subtracting the zero scale change. OUTPUT SPECIFICATIONS PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VO Voltage output range RL = 10 kΩ 0 VDD-0.4 V % of FS Output load regulation accuracy VO(OUT)= 4.096 V, 2.048 V RL = 2 kΩ 0.1 0.29 voltage 5-V Supply 100 VO(OUT) = 0 V, Full scale IOSC(source) Output short circuit source current mA code 3-V Supply 25 5-V Supply 10 IO(source) Output source current RL = 100Ω mA 3-V Supply 10 4 |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |