| 数据搜索系统,热门电子元器件搜索 |
|
TMP461-SP 数据表(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP461-SP 数据表(HTML) 21 Page - Texas Instruments |
|
21 / 36 page ![]() 21 TMP461-SP www.ti.com SBOS876B – SEPTEMBER 2017 – REVISED FEBRUARY 2020 Product Folder Links: TMP461-SP Submit Documentation Feedback Copyright © 2017–2020, Texas Instruments Incorporated 7.6.1.4 Configuration Register The configuration register sets the temperature range, the ALERT/THERM modes, and controls the shutdown mode. The configuration register is set by writing to pointer address 09h, and is read by reading from pointer address 03h. Table 7 summarizes the bits of the configuration register. Table 7. Configuration Register Bit Descriptions CONFIGURATION REGISTER (Read = 03h, Write = 09h, POR = 00h) BIT NUMBER NAME FUNCTION POWER-ON RESET VALUE 7 MASK1 0 = ALERT enabled 1 = ALERT masked 0 6 SD 0 = Run 1 = Shut down 0 5 ALERT/THERM2 0 = ALERT 1 = THERM2 0 4:3 Reserved — 0 2 RANGE 0 = –40°C to +127°C 1 = –64°C to +191°C 0 1:0 Reserved — 0 MASK1 (bit 7) of the configuration register masks the ALERT output. If MASK1 is 0 (default), the ALERT output is enabled. If MASK1 is set to 1, the ALERT output is disabled. This configuration applies only if the value of ALERT/THERM2 (bit 5) is 0 (that is, pin 7 is configured as the ALERT output). If pin 7 is configured as the THERM2 output, the value of the MASK1 bit has no effect. The shutdown bit (SD, bit 6) enables or disables the temperature-measurement circuitry. If SD = 0 (default), the TMP461-SP device converts continuously at the rate set in the conversion rate register. When SD is set to 1, the TMP461-SP device stops converting when the current conversion sequence is complete and enters a shutdown mode. When SD is set to 0 again, the TMP461-SP resumes continuous conversions. When SD = 1, a single conversion can be started by writing to the one-shot start register; see the One-Shot Start Register section for more information. ALERT/THERM2 (bit 5) sets the configuration of pin 7. If the ALERT/THERM2 bit is 0 (default), then pin 7 is configured as the ALERT output; if this bit is set to 1, then pin 7 is configured as the THERM2 output. The temperature range is set by configuring RANGE (bit 2) of the configuration register. Setting this bit low (default) configures the TMP461-SP device for the standard measurement range (–40°C to +127°C); temperature conversions are stored in the standard binary format. Setting bit 2 high configures the TMP461-SP device for the extended measurement range (–64°C to +191°C); temperature conversions are stored in the extended binary format (see Table 2). The remaining bits of the configuration register are reserved and must always be set to 0. The power-on reset value for this register is 00h. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |