| 数据搜索系统,热门电子元器件搜索 |
|
TMP461-SP 数据表(PDF) 13 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMP461-SP 数据表(HTML) 13 Page - Texas Instruments |
|
13 / 36 page ![]() 50 60 70 80 90 100 ALERT THERM Limit THERM Limit - Hysteresis High Temperature Limit THERM 110 120 130 140 150 Temperature Conversion Complete Time Measured Temperature ALERT output serviced by master 50 60 70 80 90 100 THERM2 THERM Limit THERM Limit - Hysteresis THERM 110 120 130 140 150 Temperature Conversion Complete Time Measured Temperature THERM2 Limit THERM2 Limit - Hysteresis 13 TMP461-SP www.ti.com SBOS876B – SEPTEMBER 2017 – REVISED FEBRUARY 2020 Product Folder Links: TMP461-SP Submit Documentation Feedback Copyright © 2017–2020, Texas Instruments Incorporated 7.3.5 Sensor Fault The TMP461-SP device can sense a fault at the D+ input resulting from an incorrect diode connection. The TMP461-SP device can also sense an open circuit. Short-circuit conditions return a value of –64°C. The detection circuitry consists of a voltage comparator that trips when the voltage at D+ exceeds (V+) – 0.3 V (typical). The comparator output is continuously checked during a conversion. If a fault is detected, then OPEN (bit 2) in the status register is set to 1. When not using the remote sensor with the TMP461-SP device, D+ must be connected to D– or GND to prevent meaningless fault warnings. 7.3.6 ALERT and THERM Functions Operation of the ALERT (pin 7) and THERM (pin 4) interrupts is shown in Figure 13. Operation of the THERM (pin 4) and THERM2 (pin 7) interrupts is shown in Figure 14. The ALERT and THERM pin setting is determined by bit 5 of the configuration register. The hysteresis value is stored in the THERM hysteresis register and applies to both the THERM and THERM2 interrupts. The value of the CONAL[2:0] bits in the consecutive ALERT register (see Table 5) determines the number of limit violations before the ALERT pin is tripped. The default value is 000b and corresponds to one violation, 001b programs two consecutive violations, 011b programs three consecutive violations, and 111b programs four consecutive violations. The CONAL[2:0] bits provide additional filtering for the ALERT pin state. Figure 13. ALERT and THERM Interrupt Operation Figure 14. THERM and THERM2 Interrupt Operation 7.4 Device Functional Modes 7.4.1 Shutdown Mode (SD) The TMP461-SP shutdown mode enables the user to save maximum power by shutting down all device circuitry other than the serial interface, and reducing current consumption to typically less than 3 μA; see Figure 10 (Shutdown Quiescent Current vs Supply Voltage). Shutdown mode is enabled when the SD bit (bit 6) of the configuration register is high; the device shuts down after the current conversion is finished. When the SD bit is low, the device maintains a continuous-conversion state. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |