5 / 22 page

MLX90609
Angular Rate Sensor (Standard version)
390109060901
Page 5 of 22
Data Sheet
Rev 007
January/08
3. MLX90609 General Electrical Specifications
DC Operating Parameters TA = -40°C to 85°C, VDD = 4.75V to 5.25V.
Parameter.
Symbol
Test Conditions
Min
Typ
Max
Units
Supply Voltage
VDD
4.75
5.25
V
Supply Current
IDD
No output load
16
20
mA
Output capacitive load to VDD or VSS
Analog output
0
100
pF
Output resistive load
Analog output
200k
∞
Ohm
Output, max
max
,Ω
OUT
U
Analog output
4.5
V
Output, min
min
, Ω
OUT
U
Analog output
0.5
V
Voltage Reference load current Note 3
IREF
Analog output
-10
10
µA
Logic Input, Low Voltage
VIL
SS , MOSI
0
0.3 x VDD
V
Logic Input, High Voltage
VIH
SS , MOSI
0.7 x VDD
VDD
V
Clock Input, Low Voltage
VILC
SCLK
0
0.8
V
Clock Input, High Voltage
VIHC
SCLK
2.8
VDD
V
Clock Input, Hysteresis Voltage
VHC
SCLK
1.1
V
Logic Output, Low Voltage
VOL
MISO, ERROR, IO < 8 mA
0
0.4
V
Logic Output, High Voltage
VOH
MISO, ERROR, IO < 8 mA
2.4
VDD
V
Input high current with pull-up
IIH_UP
SS , SCLK, VIN = VDD
-10
10
µA
Input low current with pull-up
IIL_UP
SS , SCLK, VIN = VSS
-10
-200
µA
Input high current with pull-down
IIH_DOWN
MOSI, VIN = VDD
200
10
µA
Input low current with pull-down
IIL_DOWN
MOSI, VIN = VSS
-10
10
µA
Tri-State Output Leakage current
IOZ
MISO
-10
10
µA
Table 3. DC Electrical Characteristics