24 / 32 page ![]() 24 24 1 For Input Registers, replace the 4xxxx with a 3xxxx in the above register address. The 3xxxx are a mirror of the 4xxxx Holding Registers. 2 An attempt to exceed a limit will set the register to its high or low limit value. 400 300 200 99999 99999 99999 -19999 -19999 -19999 Alternate Setpoint 4 Value (Hi word) Alternate Setpoint 3 Value (Hi word) Alternate Setpoint 2 Value (Hi word) Alternate Setpoint 4 Value (Lo word) Alternate Setpoint 3 Value (Lo word) Alternate Setpoint 2 Value (Lo word) 40047 40045 40043 40048 40046 40044 Setpoint List B Setpoint List B Setpoint List B FREQUENTLY USED REGISTERS (Continued) COMMENTS ACCESS FACTORY SETTING HIGH LIMIT 2 LOW LIMIT 2 REGISTER NAME REGISTER ADDRESS 1 Read/Write Read/Write Read/Write SERIAL RLC PROTOCOL COMMUNICATIONS RLC Communications requires the Serial Communications Type Parameter () be set to . SENDING SERIAL COMMANDS AND DATA When sending commands to the meter, a string containing at least one command character must be constructed. A command string consists of a command character, a value identifier, numerical data (if writing data to the meter) followed by a the command terminator character * or $. Command Chart COMMAND DESCRIPTION NOTES N Node (Meter) Address Specifier Address a specific meter. Must be followed by a one or two digit node address. Not required when address = 0. T Transmit Value (read) Read a register from the meter. Must be followed by register ID character V Value Change (write) Write to register of the meter. Must be followed by register ID character and numeric data. R Reset Reset a register or output. Must be followed by register ID character. P Block Print Request (read) Initiates a block print output. Registers are defined in programming. Command String Construction The command string must be constructed in a specific sequence. The meter does not respond with an error message to invalid commands. The following procedure details construction of a command string: 1. The first characters consist of the Node Address Specifier (N) followed by a 1 or 2 character address number. The address number of the meter is programmable. If the node address is 0, this command and the node address itself may be omitted. This is the only command that may be used in conjunction with other commands. 2. After the address specifier, the next character is the command character. 3. The next character is the Register ID. This identifies the register that the command affects. The P command does not require a Register ID character. It prints according to the selections made in print options. 4. If constructing a value change command (writing data), the numeric data is sent next. 5. All command strings must be terminated with the string termination characters * or $. The meter does not begin processing the command string until this character is received. See Timing Diagram figure for differences between terminating characters. Register Identification Chart 1. Register Names are also used as Register Mnemonics during full transmission. 2. The registers associated with the P command are set up in Print Options (Module 7). Unless otherwise specified, the Transmit Details apply to both T and V Commands. Command String Examples: 1. Address = 17, Write 350 to Setpoint 1 String: N17VM350* 2. Address = 5, Read Input A value String: N5TA* 3. Address = 0, Reset Setpoint 4 output String: RS* Transmitting Data To the Meter Numeric data sent to the meter must be limited to Transmit Details listed in the Register Identification Chart. Leading zeros are ignored. Negative numbers must have a minus sign. The meter ignores any decimal point and conforms the number to the scaled resolution. (ie. The meter’s scaled decimal point position is set for 0.0 and 25 is written to a register. The value of the register is now 2.5. In this case, write a value of 250 to equal 25.0). Note: Since the meter does not issue a reply to value change commands, follow with a transmit value command for readback verification. OFB SOR Input B Offset Setpoint Register J X OFA AOR Input A Offset Analog Output Register I W ABB MMR Auto/Manual Register H U ABA SP4 Setpoint 4 G S MAX SP3 Max Setpoint 3 F Q MIN SP2 Min Setpoint 2 E O TOT SP1 Total Setpoint 1 D M CLC Calculation Value C INB B INA A REGISTER NAME 1 VALUE DESCRIPTION ID COMMAND SUPPORTED2 T T, R (reset command zeros Total) T T, V T T, V T, V T, V T, V T, R (reset command zeros or tares input) T, R (reset command zeros or tares input) Input A Absolute (Gross) Value Input B Absolute (Gross) Value T, V, R (reset command resets setpoint output) T, V, R (reset command resets setpoint output) T, V, R (reset command resets setpoint output) T, V, R (reset command resets setpoint output) Input A Relative Value Input B Relative Value T, R (reset command loads current reading) T, R (reset command loads current reading) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |