25 / 32 page ![]() 25 Transmitting Data From the Meter Data is transmitted from the meter in response to either a transmit command (T), a print block command (P) or User Function print request. The response from the meter is either a full field transmission or an abbreviated transmission. See Abbreviated Printing () parameter. Full Transmission These characters only appear in the last line of a block print. The first two characters transmitted (bytes 1 and 2) are the unit address. If the address assigned is 00, two spaces are substituted. A space (byte 3) follows the unit address field. The next three characters (bytes 4 to 6) are the register mnemonic. The numeric data is transmitted next. The numeric field (bytes 7 to 18) is 12 characters long. When the requested value exceeds eight digits for count values or five digits for rate values. Byte 8 is always a space. The remaining ten positions of this field (bytes 9 to 18) consist of a minus sign (for negative values), a floating decimal point (if applicable), and eight positions for the requested value. The data within bytes 9 to 18 is right-aligned with leading spaces for any unfilled positions. The end of the response string is terminated with <CR> (byte 19), and <LF> (byte 20). When a block print is finished, an extra <SP> (byte 21), <CR> (byte 22), and <LF> (byte 23) are used to provide separation between the transmissions. Abbreviated Transmission These characters only appear in the last line of a block print. The abbreviated response suppresses the address and register mnemonics, leaving only the numeric part of the response. Meter Response Examples: 1. Address = 17, full field response, Input A = 875 17 INA 875 <CR><LF> 2. Address = 0, full field response, Setpoint 2 = -250.5 SP2 -250.5<CR><LF> 3. Address = 0, abbreviated response, Setpoint 2 = 250, last line of block print 250<CR><LF><SP><CR><LF> Auto/Manual Mode Register (MMR) ID: U This register sets the controlling mode for the outputs. In Auto Mode (0) the meter controls the setpoint and analog output. In Manual Mode (1) the outputs are defined by the registers SOR and AOR. When transferring from auto mode to manual mode, the meter holds the last output value (until the register is changed by a write). Each output may be independently changed to auto or manual. In a write command string (VU), any character besides 0 or 1 in a field will not change the corresponding output mode. U abcde e = Analog Output d = SP4 c = SP3 b = SP2 a = SP1 Example: VU00011 places SP4 and Analog in manual. Analog Output Register (AOR) ID: W This register stores the present signal value of the analog output. The range of values of this register is 0 to 4095, which corresponds to the analog output range per the following chart: *Due to the absolute accuracy rating and resolution of the output card, the actual output signal may differ 0.15% FS from the table values. The output signal corresponds to the range selected (0-20 mA, 4-20 mA or 0-10 V). Writing to this register (VW) while the analog output is in the Manual Mode causes the output signal level to update immediately to the value sent. While in the Automatic Mode, this register may be written to, but it has no effect until the analog output is placed in the manual mode. When in the Automatic Mode, the meter controls the analog output signal level. Reading from this register (TW) will show the present value of the analog output signal. Example: VW2047 will result in an output of 10.000 mA, 12.000 mA or 5.000V depending on the range selected. Setpoint Output Register (SOR) ID: X This register stores the states of the setpoint outputs. Reading from this register (TX) will show the present state of all the setpoint outputs. A “0” in the setpoint location means the output is off and a “1” means the output is on. X abcd d = SP4 c = SP3 b = SP2 a = SP1 In Automatic Mode, the meter controls the setpoint output state. In Manual Mode, writing to this register (VX) will change the output state. Sending any character besides 0 or 1 in a field or if the corresponding output was not first in manual mode, the corresponding output value will not change. (It is not necessary to send least significant 0s.) Example: VX10 will result in output 1 on and output 2 off. Byte Description 1-12 12 byte data field, 10 bytes for number, one byte for sign, one byte for decimal point 13 <CR> (Carriage return) 14 <LF> (Line feed) 15 <SP> (Space) 16 <CR> (Carriage return) 17 <LF> (Line feed) <LF> (Line feed) 23 <CR> (Carriage return) 22 <SP> (Space) 21 <LF> (Line feed) 20 3 byte Register Mnemonic field 4-6 <SP> (Space) 3 12 byte numeric data field: 10 bytes for number, one byte for sign, one byte for decimal point 7-18 2 byte Node (Meter) Address field [00-99] 1, 2 <CR> (Carriage return) 19 Description Byte 10.000 20.000 9.9975 19.996 5.000 12.000 0.0025 4.004 0.000 4.000 0-10V 4-20 mA 20.000 4095 19.995 4094 10.000 2047 Output Signal* Register Value 0.005 1 0.000 0 0-20 mA |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |