Back Button DRV5013FAQDBZR Datasheet HTML 6Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 7Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 8Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 9Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 10Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 11Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 12Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 13Page - Texas Instruments DRV5013FAQDBZR Datasheet HTML 14Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 10 / 38 page
background image
6 Detailed Description
6.1 Overview
The DRV5013 device is a chopper-stabilized Hall sensor with a digital latched output for magnetic sensing
applications. The DRV5013 device can be powered with a supply voltage ranging from 2.5 V to 38 V, and
continuously withstand –22 V reverse-battery conditions. The DRV5013 device does not operate when –22 V to
2.4 V is applied to the VCC pin (with respect to the GND pin). In addition, the device can withstand voltages up to
40 V for transient durations.
The field polarity is defined as follows: a south pole near the marked side of the package induces a positive
magnetic flux density on the sensor, while a north pole near the marked side of the package induces a negative
magnetic flux density on the sensor.
The output state is dependent on the magnetic flux density perpendicular to the package. A positive magnetic
flux density greater than the operate point threshold, BOP, causes the output to pull low for the AD, AG, BC and
FA device versions (release high for the inverted ND and FD device versions). A negative magnetic flux density
less than the release point threshold, BRP, causes the output to release high for the AD, AG, BC and FA device
versions (pull low for the inverted ND and FD device versions). Hysteresis is included in between the operate
point and the release point to help prevent magnetic noise from accidentally tripping the output.
An external pullup resistor is required on the OUT pin. The OUT pin can be pulled up to VCC, or to a different
voltage supply. This allows for easier interfacing with controller circuits.
6.2 Functional Block Diagram
Temperature
Compensation
Bias
+
±
Regulated Supply
Reference
Gate
Drive
OCP
VCC
OUT
GND
2.5 to 38 V
R1
C2
(Optional)
C1
Hall Element
DRV5013
SLIS150N – MARCH 2014 – REVISED JULY 2025
www.ti.com
10
Submit Document Feedback
Copyright © 2025 Texas Instruments Incorporated
Product Folder Links: DRV5013



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com