13 / 38 page ![]() If the device is powered on with the magnetic flux density BRP < B < BOP, then the device output is indeterminate and can either be Hi-Z or pulled low. During the power-up sequence, the output is held Hi-Z until ton has elapsed. At the end of ton, a pulse is given on the OUT pin to indicate that ton has elapsed. After ton, if the magnetic flux density changes such that BOP < B, the output is released. Case 3 (Figure 6-6) and Case 4 (Figure 6-7) show examples of this behavior. VCC BOP BRP t (s) B (mT) t (s) t (s) OUT Valid Output td ton Figure 6-6. Case 3: Power On When BRP < B < BOP, Followed by B > BOP VCC BOP BRP t (s) B (mT) t (s) t (s) OUT Valid Output td ton Figure 6-7. Case 4: Power On When BRP < B < BOP, Followed by B < BRP www.ti.com DRV5013 SLIS150N – MARCH 2014 – REVISED JULY 2025 Copyright © 2025 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: DRV5013 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|