STPM11ATR 数据表(HTML) 39 Page - STMicroelectronics |
|
39 / 46 page ![]() STPM11, STPM12, STPM13, STPM14 STPM1x calibration Doc ID 13167 Rev 8 39/46 Note: STPM13/14: each current channel must be calibrated separately. In order to do this, follow these steps: Apply the nominal test voltage to the voltage sensor, and the nominal test current to the primary current channel sensor. Do not apply such current on the secondary current channel sensor. Adjust the voltage and primary current calibrators (see above). Disconnect the nominal test current from the primary current channel sensor, and apply it to the secondary current channel sensor. Adjust only the secondary current calibrators, so that the same power is computed. Obsolete Product(s) - Obsolete Product(s) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|