| 数据搜索系统,热门电子元器件搜索 |
|
TLV73311PDBVR.A 数据表(PDF) 15 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TLV73311PDBVR.A 数据表(HTML) 15 Page - Texas Instruments |
|
15 / 38 page ![]() 15 TLV733P www.ti.com SBVS235C – OCTOBER 2014 – REVISED JULY 2019 Product Folder Links: TLV733P Submit Documentation Feedback Copyright © 2014–2019, Texas Instruments Incorporated 7.4 Device Functional Modes 7.4.1 Normal Operation The device regulates to the nominal output voltage under the following conditions: • The input voltage has previously exceeded the UVLO rising voltage and has not decreased below the UVLO falling threshold. • The input voltage is greater than the nominal output voltage added to the dropout voltage. • The enable voltage has previously exceeded the enable rising threshold voltage and not decreased below the enable falling threshold. • The output current is less than the current limit. • The device junction temperature is less than the thermal shutdown temperature. 7.4.2 Dropout Operation If the input voltage is lower than the nominal output voltage plus the specified dropout voltage, but all other conditions are met for normal operation, the device operates in dropout mode. In this condition, the output voltage is the same the input voltage minus the dropout voltage. The transient performance of the device is significantly degraded because the pass device is in a triode state and no longer controls the current through the LDO. Line or load transients in dropout may result in large output voltage deviations. 7.4.3 Disabled The device is disabled under the following conditions: • The input voltage is less than the UVLO falling voltage, or has not yet exceeded the UVLO rising threshold. • The enable voltage is less than the enable falling threshold voltage or has not yet exceeded the enable rising threshold. • The device junction temperature is greater than the thermal shutdown temperature. When the device is disabled, the active pulldown resistor discharges the output. Table 1 shows the conditions that lead to the different modes of operation. Table 1. Device Functional Mode Comparison OPERATING MODE PARAMETER VIN VEN IOUT TJ Normal mode VIN > VOUT(nom) + VDO and VIN > UVLORISE VEN > VEN(HI) IOUT < ILIM TJ < 160°C Dropout mode UVLORISE < VIN < VOUT(nom) + VDO VEN > VEN(HI) IOUT < ILIM TJ < 160°C Disabled mode (any true condition disables the device) VIN < UVLOFALL VEN < VEN(LO) — TJ > 160°C |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |