3 / 4 page ![]() Fitting Instructions Fitting instructions must be followed each time the respirator is worn. 1. Fully loosen all four head straps, then place the harness at back of head and position facepiece over the face. 2. Pull the ends of the four straps to adjust tightness, starting with the neck straps first, then the forehead straps. Do not over tighten the head straps. 3. Perform a positive and/or negative pressure fit check each time the respirator is donned. Cleaning and Storage For cleaning after use the 3M 105 face piece cleaner can be used • Disassemble by removing the filters and nose cup. • The centre adapter, lens and faceseal can also be removed if necessary. • Clean and sanitise the facepiece (excluding cartridges and filters) by immersing in warm cleaning solution and scrub with soft brush until clean. Parts may also be cleaned in a washer. Note : Water temperature should not exceed 50°C. Do not use cleaning agents that contain lanolin or other oils. • Disinfect respirator by soaking in a solution of quaternary ammonia disinfectant or sodium hypochlorite (50ppm chlorine). • Rinse in fresh, warm water and air dry in a non-contaminated atmosphere. Drying temperatures must not exceed 50°C. • Respirator components, especially exhalation valve and seat, should be inspected prior to each use. Any damaged or deteriorated components should be replaced. • The cleaned respirator should be stored at ambient temperature in a dry non-contaminated atmosphere. Face Fitting Positive pressure facefit check: • Place the palm of the hand over the exhalation valve cover and exhale gently. • If the facepiece bulges slightly and no air leaks between the face and the facepiece are detected, a proper fit has been achieved. • If air leakage is detected, reposition the respirator on the face and/or readjust the tension of the straps to eliminate the leakage. • Repeat the above facefit check. Negative pressure facefit check: • For the 2000 Series filters, press your thumbs into the central indentation of the filters, inhale gently and hold your breath for five or ten seconds. • For the 6035 and 6038 filters, pinch the filter between thumb and fingers to seal the filter cover to the body of the filter, inhale gently and hold your breath for five or ten seconds. If the facepiece collapses slightly a proper fit has been achieved. • If air leakage is detected, reposition the respirator on the face and/or readjust the tension of the straps to eliminate the leakage. • Repeat the above facefit check. Fit Testing The 6000 Full Face Mask is a tight fitting facepiece and therefore requires a fit test per wearer before use as per the COSHH regula- tions 2002. For quantitative fit testing - the 3M 601 adaptor is available. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |