| 数据搜索系统,热门电子元器件搜索 |
|
AD300-R04D-CIT 数据表(PDF) 2 Page - Honeywell Solid State Electronics Center |
|
|
|||||||||||||||||||||||||||||
AD300-R04D-CIT 数据表(HTML) 2 Page - Honeywell Solid State Electronics Center |
|
2 / 5 page ![]() INTELLIGENT SERIES GAS SENSORS (iSERIES) iSO2 SERIES iSO2 Series Gas Sensor Datasheet | sps.honeywell.com/ast | 2 20,0 (includes label) 10,0 ±0,2 45° ‡ (O-ring) 7,00 ±0,10 6,75 CS Ve +V ‡ For mounting and sealing around sensor, refer to iseries Sensor Mounting Application Note. Do not obscure Rx Tx 3,6 Ø 2,00 Shorting pads 3 posn. 2,0 typ. 5,4 10,8 3,6 1,8 Product Dimensions All dimensions in mm Do not connect to unlabeled pins. TABLE 2. ELECTRICAL SPECIFICATIONS Min. Max. Typ. Unit Supply Voltage (Vdd) 3 3.6 3.3 Vdc Voltage of any pin relative to ground 0 3.6 – Vdc Peak supply current (typ. volt) 25 mA Current: at stand-by mode – – 15.31 mA Current: at active mode – – 26.36 mA Average power consumption 0.046 90 0.087 mW For compatibility with the whole iseries range, the supply voltage should be between 3.1 V and 3.3 V. TABLE 3. PINOUT Pin Description +V Positive power supply -V Ground Rx Data transmitted from instrument to sensor Tx Data transmitted from sensor to instrument CS Chip Select Other Pads Do not connect, shorting link contacts only TABLE 1. TECHNICAL SPECIFICATIONS MEASUREMENT Operating Principle Electrochemical Target Gas SO 2 Range 0 to 20 ppm Accuracy ±5% of measuring value Filter To remove H 2S Capacity: 400 ppm hours to 25 ppm H 2S T90* Response Time <30 seconds, typ. T50* Response Time <10 seconds Output ppm output compensated for temperature Overload (maximum concentration that can be reached before damaging the sensor) 150 ppm Linearity* Linear (±5% from linear up to 20 ppm) Measurement Interval 1 sample per second (1 Hz) Resolution 0.1 ppm Baseline (Offset)* <-0.2 ppm to 0.5 ppm equivalent Zero Shift 20°C to 40°C <0.2 ppm equivalent Repeatability* ±2% of measured value Orientation Sensitivity None Warm-up Time Approximately 30 minutes for accurate measurements (see iSO2 characterisation note for details). Serial Comunication UART with Chip Select ENVIRONMENTAL Operating Temperature Range -20°C to 50°C (continuous) -40°C to 55°C (intermittent) Operating Humidity Range 15% RH to 90% RH (non-condensing). Extended exposure to extreme humidity conditions will degrade sensor performance Operating Pressure Range 600 mbar to 1200 mbar Recommended Storage Temperature 0°C to 20°C Flow Rate Typical: 200 ml/min when using recommended gassing hood. (Consult iseries Sensor Mounting Application Note) LIFETIME Long-Term Output Drift* <10% signal loss per annum Expected Operating Life ** 5 years in air PHYSICAL CHARACTERISTICS Weight <6 g Contact Material Gold plated O-Ring Material FKM60 ±5 shore A Outer Plastic Body Material Modified PPO * Specifications are valid at 20°C, 50% RH, and 1013 mbar using Honeywell recommended circuitry. Performance characteristics outline the performance of sensors supplied within the first three months. Output signal can drift below the lower limit over time. ** Depends on environmental conditions |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |