3 / 5 page ![]() INTELLIGENT SERIES GAS SENSORS (iSERIES) iSO2 SERIES iSO2 Series Gas Sensor Datasheet | sps.honeywell.com/ast | 3 TABLE 4. iSO2 PARAMETERS iSO2 parameters Default Values Configurable Range Notes OEM code (First level) Password is customisable.* ( NoLock will be set by default in case the OEM lock is not required) No more than 6 characters (ASCII format) ü * OEM code will be set by Honeywell during sensor manufacturing. Code to be provided by OEM Partner code (Second level) – No more than 6 characters (ASCII format) ü Once this code has been set by user, it is not possible to change it User factor 0: 100 User factor 1: 90 UF 2-3: Reserved UF 4-9: Customisable ––––––––––– User factors can be added to include auto- compensation for using different membranes or instruments 10 allocated slots ––––––––––– 2 user factors are already implemented (no additional membrane and with recommended membrane), 2 are reserved and the remaining 6 can be customised ü * ü ** * User factor 0 and 1 programmed into the sensor during manufacturing. Additional User Factors can be added to the selectable list during the manufacturing process. This user factor has to be provided by the user. ** Users can select the desired user factor from the selectable list Zero (clean air) 0 ppm û Calibration is performed at two points throughout the operating range of the sensor. The calibration points are defined by the zero and span values. The zero value represent the response of the sensor in clean air Span (target gas) 20 ppm ü Span is the calibration point that is done in the presence of the target gas. The span concentration can be configured through the communication protocol Low 2 ppm Limit LOW lower: 0.2 Limit LOW upper: 100 ü High 10 ppm Limit HIGH lower: 0.2 Limit HIGH upper: 100 ü STEL 5 ppm over 15 minutes Limit STEL lower: 0.2 Limit STEL upper: 100 ü Short-Term Exposure Limit: STEL is a limit value above which exposure to a chemical substance should not occur. It usually references a 15-minute period. STEL works to prevent adverse health effects along with other unwanted effects due to peak exposure that could possibly not be controlled by the application of an 8 hour TWA limit TWA 2 ppm over 8 hours Limit TWA lower: 0.2 Limit TWA upper: 1000 ü Time-Weighted Average: TWA for chemical exposure can be used when each of the chemical concentration and time for exposure varies over time. It conveys the average exposure to a contaminant to which workers may be exposed without adverse effect over a period of time such as an 8-hour day or 40-hour week (an average work shift). The measurement is expressed in units of ppm The recalibration alarm will be triggered when either the countdown or the accuracy threshold are reached (whichever is triggered first). Countdown timer (Cal due days) 180 days ü The alarm will be flagged when the countdown reaches 0. The countdown restarts when the sensor is calibrated Accuracy threshold ±20% ±10% to ±50% ü The predictive calibration estimation will depend on the accuracy of the sensor (this parameter can be configured by the user). The tighter the accuracy value, the more frequent calibration needed. The sensor will request a recalibration when the default accuracy (±20% of measuring value) is reached The EoL alarm will be triggered when either the countdown or the future prediction algorithm conditions are met Future prediction algorithm û The algorithm triggers an alarm when the sensitivity < 50% of original sensitivity at minimum recent temperature Countdown timer 1825 days û The countdown timer is set for 1825 days, i.e. 5 years Active by default ü ü With the deadband enabled the sensor will read zero until the concentration exceeds the deadband value. Is normally used to prevent measurement oscillations. This function can be configured to different limits Incoming 1 ppm Whole measurement range ü Incoming: As the reading decays down it will read zero once it has fallen below the incoming threshold Outgoing 1 ppm Incoming < Outgoing ü Outgoing: As the reading increases it will read zero until it exceeds the outgoing threshold 1 day ü A bump test is a brief exposure of the sensor to the target gas. The test has the objective of verifying that the sensor responds and the instrument acts accordingly. The sensor will tell the user when the bump interval has been exceeded. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |