| 数据搜索系统,热门电子元器件搜索 |
|
STPM11ATR 数据表(PDF) 30 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPM11ATR 数据表(HTML) 30 Page - STMicroelectronics |
|
30 / 45 page ![]() Theory of operation STPM11/12/13/14 30/45 The mode signals bit can be written using the normal writing procedure of the CFGI interface (see CFGI par. 7.17) – RD mode signal has been already described in par. 7.15 (configuring the STPM1x), but there is another implied function of the signal RD. When it is set, each sense amplifier is disconnected from corresponding anti-fuse element and this way, its 3V NMOS gate is protected from the high voltage of VOTP during permanent write operation. This means that as long as the VOTP voltage reads more than 3V, the signal RD should be set. – PUMP. When set, the PUMP mode signal transforms the MOP and MON pins to act as driving signals to implement a charge-pump DC-DC converter (see Figure 23). This feature is useful in order to boost the VCC supply voltage of the STPM1x to generate the VOTP voltage (14 V to 20 V) needed to program the OTP anti-fuse elements. – WE (write Enable): This mode signal is used to permanently write to the OTP anti- fuse element. When this bit is not set, any writing to the configuration bit is recorded in the shadow latches. When this bit is set, the writing is recorded both in the shadow latch and in the OTP anti-fuse element. 7.17 CFGI: Configuration interface The CFGI interface supports a simple serial protocol, which is implemented in order to enable the configuration of STPM1x which allows writing the Mode bits and the configuration bits (temporarily or permanently); Four pins of the device are dedicated to this purpose: SCS, SYN-NP, SCLNCN, SDATD. SCS, SYN-NP, SCL-NLC and SDATD are all input pins. A high level signal for these pins means a voltage level higher than 0.75xVCC, while a low level signal means a voltage value lower than 0.25xVCC. The condition in which SCS, SYN-NP and SCL-NLC inputs are set to high level determines the idle state of the CFGI interface and no data transfer occurs. – SCS: in the STPM1X, the SYN-NP, SCL-NLC and SDA-TD have the dual task to provide information on the meter status (see Pin Description table) and to allow CFGI communication. The SCS pin allows using the above pins for CFGI communication when it is low and allows the normal operation of SYN-NP, SCL-NLC and SDA-TD Table 15. Mode signals description Signal Name Bit Value Status Binary Command Hex Command PUMP 0 MOP and MON operate normally 0111000x 70 or 71 1 MOP and MON provide the driving signals to implement a charge-pump DC-DC converter 1111000x F0 or F1 RD 0 The 56 Configuration bits originated by OTP anti-fuses 0111101x 7A or 7B 1 The 56 Configuration bits originated by shadow latches 1111101x FA or FB WE 0 Any writing in the configuration bits is recorded in the shadow latches 0111110x 7C or 7D 1 Any writing in the configuration bits is recorded both in the shadow latches and in the OTP anti-fuse elements 1111110x FC or FD |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |