58 / 75 page ![]() 59 — RCCB F 200 series Technical features Features Specifications F 200AC Electrical features Standards IEC/EN 61008-1; IEC/EN 61008-2-1, UL 1053 (¹) Type (wave form of the earth leakage – AC Poles – 2P, 4P (for 125 A only 4P) Rated current In A 16, 25, 40, 63, 80, 100, 125 Rated sensitivity IΔn A 0.01-0.03-0.1-0.3-0.5 50/60Hz Rated voltage Ue V 230/400 - 240/415 V 480Y/277 (up to 100 A Insulation voltage Ui – V 500 Max. operating voltage of circuit test V 110(185for125A);195forF200leftneutral 170 (150 for 125 A); 300 for F 200 left neutral for IDn = 30 mA (⁵) V 277(upto100A);480forF200leftneutral(⁴ Min. operating voltage of circuit test V 110(185for125A);195forF200leftneutral 170 (150 for 125 A); 300 for F 200 left neutral for IDn = 30 mA (⁵) Rated frequency Hz 50…60 Rated conditional short-circuit current Inc=IΔ (³) kA 277 (up to 100 A); 480 for F 200 left neutral (⁴ Rated residual breaking capacity IΔm=Im kA 1 (1.25 for 125 A) Rated impulse withstand voltage (1.2/50) U imp kV 4 Dielectric test voltage at ind. freq. for 1 min. kV 2.5 Overvoltage category – III, disconnector abilities Surge current resistance (wave 8/20) A 250 Mechanical features Toggle – Blue sealable in ON-OFF position Contact position indicator (CPI) – Yes Electrical life – – 10000 (2000 for 125 A) Mechanical life – – 20000 (5000 for 125 A) Protection degree Housing IP4X Terminals IP2X Environmental conditions (damp heat) acc. to IEC/EN 60068-2- 30 °C/RH 28 cycles with 55°C/90-96% and 25°C/95 Ambienttemperature(withdailyaverage≤+35°C) °C -25…+55 (-25...+40 for 125A) Storage temperature – °C -40…+70 Installation Terminal type Failsafe bi-directional cylinder-lift terminal at top and bottom (shock protected) (cage for In > 63A) (2) Terminal size top/bottom for cable mm2 25/25(35/35singleslotterminalforIn>63A) UL/CSA AWG 18-4 (up to 63A) Terminal size top/bottom for busbar IEC mm2 10/10 (not for In = 80-100A) UL/CSA AWG 18-8 (up to 63A) Tightening torque Nm 2.8 (3 for In = 125A) UL/CSA in-lbs. 25 (up to 63A) Tool – Nr. 2 Pozidriv Mounting – On DIN rail EN 60715 (35mm) by means of fast clip device Connection – From top and bottom Withdrawal from busbar – It is possible without using any tools only from the bottom (not for 125A) Dimensions and weight Dimensions (H x D x W) mm 85 x 69 x 35 Weight g 200 Combination with auxiliary elements Combinable with: Auxiliary contact Yes (no for 125A) Signal contact/auxiliary switch Yes Shunt trip Yes (no for 125A) undervoltage release Yes (no for 125A) — Technical features (¹) Ground-fault sensing and relaying equipment-component (up to 63 A). (²) Prior to connection of aluminium conductors (≥ 4 mm²) ensure that their contact points are cleaned, brushed and coated with grease. (³) For S700-E/K 100A, S750-E 63A, S750DR-E/K 63A and other SCPD coordination values see Chapter 3 of Solutions for electrical distribution in buildings – technical details. (⁴) F200 left neutral has not the UL certification and the UL mark. (5) Only for versions with marking according to EN 61008-1; EN 61008-2-1. R CC B F 2 0 0 SER I E S - T EC H N I C A L FE AT U R E S |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |