| 数据搜索系统,热门电子元器件搜索 |
|
EPP-R5090 数据表(PDF) 59 Page - ABB |
|
|
|||||||||||||||||||||||||||||
EPP-R5090 数据表(HTML) 59 Page - ABB |
|
59 / 75 page ![]() 60 PROTEC TA PLUS MCB DIS TR IBUTION B OA R D 2 5 0A — EQ Meter - A series Technical features — Technical features A41 A43 Voltage/current inputs Nominal voltage 230 V AC 3x230/400 V AC Voltage range 57.7 - 288 V AC (-20% - +15%) 3x57.7/100 ... 288/500 V AC (-20% - +15%) Power dissipation voltage circuits 0.8 VA (0.8 W) total Power dissipation current circuits 0.007 VA (0.007 W) at 230 V AC and I b 0.007 VA (0.007 W) per phase at 230 V AC and I b Base current I b 5 A 5 A Rated current I n - - Reference current I ref 5 A 5 A Transitional current I tr 0.5 A 0.5 A Maximum current I max 80 A 80 A Minimum current I min 0.25 A 0.25 A Starting current I st < 20 mA < 20 mA Terminal wire area 1 - 25 mm2 1 - 25 mm2 Recommended tightening torque 3 Nm 3 Nm Communication Terminal wire area 0.5 - 1 mm2 0.5 - 1 mm2 Recommended tightening torque 0.25 Nm Transformer ratios Configurable voltage ratio (VT) - - Configurable current ratio (CT) - - Pulse indicator (LED) Pulse frequency 1000 imp/kWh 1000 imp/kWh Pulse length 40 ms 40 ms General data Frequency 50 or 60 Hz ± 5% Accuracy Class B (Cl.1) or Reactive Cl. 2 A (Cl.2), B (Cl.1) or Reactive Cl. 2 Active energy 1% 1%, 2% Display of energy Pixel oriented Environmental Operating temperature -40°C - +70°C Storage temperature -40°C - +85°C Humidity 75% yearly average, 95% on 30 days/year Resistance to fire and heat Terminal 960°C, cover 650°C (IEC 60695-2-1) Resistance to water and dust IP20 on terminal block without protective enclosure and IP51 in protective enclosure, according to IEC 60529. Mechanical environment Class M2 in accordance with the Measuring Instrument Directive (MID). (2004/22/EC). Electromagnetic environment Class E2 in accordance with the Measuring Instrument Directive (MID), (2004/22/EC). Outputs Current 2 - 100 mA Voltage 5 - 240 V AC/DC. For meters with only 1 output, 5 - 40 V DC. Pulse output frequency Programmable: 1 - 999999 imp/kWh Pulse length Programmable: 10 - 990 ms Terminal wire area 0.5 - 1 mm2 Recommended tightening torque 0.25 Nm Inputs Voltage 0 - 240 V AC/DC OFF 0 - 12 V AC/DC ON 57-240 V AC/24 - 240 V DC Min. pulse length 30 ms Terminal wire area 0.5 - 1 mm2 Recommended tightening torque 0.25 Nm EMC compatibility Impulse voltage test 6 kV 1.2/50 µs (IEC 60060-1) Surge voltage test 4 kV 1.2/50 µs (IEC 61000-4-5) Fast transient burst test 4 kV (IEC 61000-4-4) Immunity to electromagnetic HF-fields 80 MHz - 2 GHz at 10 V/m (IEC 61000-4-3) Immunity to conducted disturbance 150 kHz - 80 MHz, (IEC 61000-4-6) Immunity to disturbance with harmonics 2kHz - 150kHz Radio frequency emission EN 55022, class B (CISPR22) Electrostatic discharge 15 kV (IEC 61000-4-2) Standards IEC 62052-11, IEC 62053-21 class 1 & 2, IEC 62053-22 class 0,5 S, IEC 62053-23 class 2, IEC 62054-21, GB/T 17215.211-2006, GB/T 17215.321-2008 class 1 & 2, GB/T 17215.322-2008 class 0,5 S, GB 4208-2008, EN 50470-1, EN 50470-3 category A, B & C Mechanical Material Polycarbonate in transparent front glass, bottom case, upper case and terminal cover, Glass reinforced polycarbonate in terminal block. Dimensions Width 70 mm 123 mm Height 97 mm 97 mm Depth 65 mm 65 mm DIN modules 4 7 *) Only A44 552 - 110 and A44 553 - 110 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |