数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

WFES4530S 数据表(PDF) 7 Page - Whirlpool.

部件名 WFES4530S
功能描述  WHIRLPOOL® ELECTRIC FREE STANDING RANGES
PDF  21 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  WHIRLPOOL [Whirlpool.]
网页  https://www.whirlpool.com/
标志 WHIRLPOOL - Whirlpool.

WFES4530S 数据表(HTML) 7 Page - Whirlpool.

Back Button WFES4530S Datasheet HTML 3Page - Whirlpool. WFES4530S Datasheet HTML 4Page - Whirlpool. WFES4530S Datasheet HTML 5Page - Whirlpool. WFES4530S Datasheet HTML 6Page - Whirlpool. WFES4530S Datasheet HTML 7Page - Whirlpool. WFES4530S Datasheet HTML 8Page - Whirlpool. WFES4530S Datasheet HTML 9Page - Whirlpool. WFES4530S Datasheet HTML 10Page - Whirlpool. WFES4530S Datasheet HTML 11Page - Whirlpool. Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 21 page
background image
DIMENSION GUIDE
7 of 21
Wire sizes and connections must conform with the rating of
the range.
The Tech Sheet is located on the back of the range inside a
clear plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
neutral by a link. The ground must be revised so the green
ground wire of the 4-wire power supply cord is connected to the
cabinet. See the “Electrical Connection - U.S.A. Only” section.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250 V, 40 A or 50 A, range power
supply cord (pigtail) must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50P plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power cord
are:
40 A circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-8 green grounding
If connecting to a 3-wire system:
Local codes may permit the use of a UL listed, 3-wire, 250 V,
40 A or 50 A range power supply cord (pigtail). This cord contains
3 copper conductors with ring terminals or open-end spade
terminals with upturned ends, terminating in a NEMA Type
10-50P plug on the supply end. Connectors on the appliance end
must be provided at the point the power supply cord enters the
appliance. This uses a 3-wire receptacle of NEMA Type 10-50R.
3-wire receptacle (10-50R)
Electrical Requirements - Canada
Only
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate
and in conformance with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
Range Rating*
Specified Rating of
Power Supply Cord Kit
and Circuit Protection
120/240 V
120/208 V
Ampere
8.8-16.5 kW
16.6-22.5 kW
7.8-12.5 kW
12.6-18.5 kW
40 or 50**
50**
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**For 50 A rated cord kits, use kits that specify use with a nominal
13/8" (34.9 mm) diameter connection opening.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range’s final location.
Do not use an extension cord.
WARNING
Electrical Shock Hazard
Electrically ground range.
Failure to do so can result in death, fire, or
electrical shock.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com