| 数据搜索系统,热门电子元器件搜索 |
|
C152 数据表(PDF) 2 Page - Time Electronics Ltd. |
|
|
|||||||||||||||||||||||||||||
C152 数据表(HTML) 2 Page - Time Electronics Ltd. |
|
2 / 2 page ![]() Time Electronics 1017 Voltage/Current/Resistance Calibrator Time Electronics Ltd, Unit 5, TON Business Park, 2-8 Morley Road, Tonbridge, Kent, TN9 1RA, United Kingdom T: +44 (0) 1732 355993 | F: +44 (0) 1732 350198 | mail@timeelectronics.co.uk | www.timeelectronics.com v2c 02/24 Due to continuous development Time Electronics reserves the right to change specifications without prior notice. Technical Specifications Voltage ranges / accuracy.........................................0 to 9.99999 mV in 10 nV steps / ± 0.02 % of setting ± 0.005 % of range. ......................................................................................0 to 99.9999 mV in 100 nV steps / ± 0.01 % of setting ± 0.004 % of range. ......................................................................................0 to 999.999 mV in 1μV steps / ± 0.005 % of setting ± 0.002 % of range. ......................................................................................0 to 9.99999 V in 10 μV steps / ± 0.005 % of setting ± 0.002 % of range. ......................................................................................0 to 99.9999 V in 100 μV steps / ± 0.01 % of setting ± 0.004 % of range. The above accuracies are independent of thermal emfs which can be 2 μV or more depending on the type of leads and connections used. Output resistance.......................................................10 mV and 100 mV: 10 Ω. 1 V and 10 V: < 150 mΩ. 100 V: < 1 Ω. Drive current max .......................................................10 and 100 mV: as 10 Ω output resistance. 1 V and 10 V: 150 mA; 100 V: 10 mA. Current range / accuracy...........................................0 to 99.9999 mA in 0.1 μA steps / ± 0.02 % of setting ± 0.004 % of range. Drive voltage max.......................................................10 V. Resistance range / accuracy.....................................0 to 9.99999 kΩ in 0.01 Ω steps / ± 0.05 % of full scale. Power rating................................................................0.25 W per resistor. Residual resistance....................................................Less than 200 mΩ. Deviation control (V&I)...............................................0 % to 0.999 % in 0.001 % steps. Deviation accuracy: V and I output, 0.5 %. Temperature coefficient .............................................Voltage and current ranges: < 10 ppm/°C. Resistance ranges: < 30 ppm/°C. Long term stability......................................................5 ppm/day, < 15 ppm/90-day, < 25 ppm/year. Short term stability – noise........................................10 mV range: < 0.2 μV/sec, < 0.3 μV/10sec, < 0.4 μV/min. ......................................................................................100 mV range: < 0.2 μV/sec, < 0.4 μV/10 sec, < 0.6 μV/min. ......................................................................................1 V range: < 0.2 μV/sec, < 0.5 μV/10sec, < 1.5 μV/min. ......................................................................................10 V range: < 1.0 μV/sec, < 2.0 μV/10sec, < 8.0 μV/min. ......................................................................................100 V range: <4 0 μV/sec, < 100 μV/10sec, < 500 μV/min. ......................................................................................100 mA range: < 0.2 μA/sec, < 0.4 μA/10sec, < 1.0 μA/min. Warm-up and settling time ........................................Warm-up: < 10 mins to full accuracy. Settling: < 0.5 secs, 100 V range: 5 secs. Output connections....................................................The output is via low thermal emf terminals (0.2 μV/°C). A mains earth terminal is provided ......................................................................................for screening purposes. Output polarity can be selected by a switch on the front panel. Power supply ..............................................................The 1017 can be powered continuously from a 230 V 50/60 Hz (110 V to order) mains supply, ......................................................................................or from the internal rechargeable battery pack. Battery level indicator ................................................A front panel LED provides an indication of the battery condition. General Specifications Operating temperature ..............................................0 to 50 °C (32 to 120 °F). Full specification: 23 °C ± 5 °C. Operating humidity.....................................................10 to 90 % non-condensing 25 °C (77 °F). Dimensions .................................................................W 250 x H 119 x D 314 mm. Weight..........................................................................2.4 kg. Optional extras ...........................................................Calibration certificates - traceable (factory) or accredited (ISO 17025). Country of origin.........................................................UK. Ordering Information 1017 .............................................................................Multifunction Voltage/Current/Resistance Calibrator C152.............................................................................Traceable calibration certificate (Factory) C109.............................................................................Accredited calibration certificate (ISO 17025) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |