3 / 3 page ![]() INSTRUCTION LEAFLET WARNING: DO NOT USE NORMAL LOW VOLTAGE TRANSFORMERS WITH LEDS. All LED fittings are tested before dispatch. It is not necessary to check them on site. Do not power up until fittings are wired correctly. This product should be installed by a qualified electrician in accordance with all current, local legislation. For the UK, the current edition of the IEE Wiring Regulations and European Standard IEC 60364. LightGraphix, 20 Bourne Rd Ind. Park, Crayford, Kent, DA1 4BZ Issue: 16 Jul 2014 LightGraphix reserves the right to change specification without notice IPKit10 IP68 Connection Resin Kit for Wet/Exterior Environments WARNING Refer to specified driver sheet for correct wiring instructions. Do not switch on power source prior to making these connections as this will result in the LEDs being overvolted and can lead to LED failure. Do not switch on power until resin has had enough time to cure as stated in the instructions above. Do not pour resin on live connections. Connect pairs of cables (e.g. red + / black -) from LED fittings to specified driver. Multiple fittings of constant current LEDs are wired in series. POLARITY IS CRITICAL! If LEDs don’t work, turn power off immediately, then check polarity. Failure to do so will excessively heat up the LED, causing them to fail. A maximum no. of 10 connections can be achieved with one IP68 connection kit WIRING Page 2/2 + - red black + red - black + red - black to next fitting driver IN-SERIES CONNECTION FOR CONSTANT CURRENT WIRING 10 connections for 11 LED fittings. LED fitting 4 LED fittings per IP connection. PARALLEL CONNECTION FOR CONSTANT VOLTAGE WIRING - black + red cable from driver fitting №2 fitting №1 + red - black IN-SERIES EXAMPLE Take time to prepare all connections, use tape to hold cables and containers in an upright position. Keep cables and terminal blocks centralised within the container. Connections will not be able to bear weight until fully cured (a minimum of 48hrs). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |