| 数据搜索系统,热门电子元器件搜索 |
|
AS3688 数据表(PDF) 23 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS3688 数据表(HTML) 23 Page - ams-OSRAM AG |
|
23 / 72 page ![]() AS3688 austriami crosyst ems Datasheet, Confidential www.austriamicrosystems.com (ptr,tje) Revision 1.1.1 / 20060707 21 - 70 CP Control Addr: 23h This register controls the Charge Pump. Bit Bit Name Default Access Description 0 cp_clk 0 R/W Clock frequency selection. 0 = 1 MHz 1 = 500 kHz 2:1 cp_mode 00b R/W Charge Pump mode (in manual mode sets this mode, in automatic mode reports the actual mode used) 00 = 1:1 mode 01 = 1:1.5 mode 10 = 1:2 mode 11 = NA Note: Direct switching from 1:1.5 mode into 1:2 in manual mode and vice versa is not allowed. Always switch over 1:1 mode. 4:3 cp_mode_switching 00b R/W Set the mode switching algorithm: 00 = Automatic Mode switching; 1:1, 1:1.5 and 1:2 allowed 1 01 = Automatic Mode switching; only 1:1 and 1:1.5 allowed 1 10 = Manual Mode switching; register cp_mode defines the actual charge pump mode used 11 = reserved 6 cp_auto_on 0 R/W 0 = Charge Pump is switched on/off with cp _on 1 = Charge Pump is automatically switched on if a current sink, which is connected to the charge pump (defined by registers CP Mode Switch 1 & 2) is switched on Note : 1. Don’t use automatic mode switching together with external PWM for the current sources connceted to the charge pump with less than 500us high time. CP Mode Switch 1 Addr: 24h Setup which current sinks are connected (via leds) to the charge pump; if set to ‘1’ the correspond current source (sink) is used for automatic mode selection of the charge pump Bit Bit Name Default Access Description 0 curr30_on_cp 0 R/W 0 = current Sink CURR30 is not connected to charge pump 1 = current sink CURR30 is connected to charge pump 1 curr31_on_cp 0 R/W 0 = current Sink CURR31 is not connected to charge pump 1 = current sink CURR31 is connected to charge pump 2 curr32_on_cp 0 R/W 0 = current Sink CURR32 is not connected to charge pump 1 = current sink CURR32 is connected to charge pump 3 curr33_on_cp 0 R/W 0 = current Sink CURR33 is not connected to charge pump 1 = current sink CURR33 is connected to charge pump 4 rgb1_on_cp 0 R/W 0 = current Sink RGB1 is not connected to charge pump 1 = current sink RGB1 is connected to charge pump 5 rgb2_on_cp 0 R/W 0 = current Sink RGB2 is not connected to charge pump 1 = current sink RGB2 is connected to charge pump 6 rgb3_on_cp 0 R/W 0 = current Sink RGB3 is not connected to charge pump 1 = current sink RGB3 is connected to charge pump 7 NA |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |