60 / 131 page ![]() ST7LITE2 60/131 12-BIT AUTORELOAD TIMER (Cont’d) 11.2.6 Register Description TIMER CONTROL STATUS REGISTER (ATCSR) Read / Write Reset Value: 0x00 0000 (x0h) Bit 7 = Reserved. Bit 6 = ICF Input Capture Flag. This bit is set by hardware and cleared by software by reading the ATICR register (a read access to ATICRH or ATICRL will clear this flag). Writing to this bit does not change the bit value. 0: No input capture 1: An input capture has occurred Bit 5 = ICIE IC Interrupt Enable. This bit is set and cleared by software. 0: Input capture interrupt disabled 1: Input capture interrupt enabled Bits 4:3 = CK[1:0] Counter Clock Selection. These bits are set and cleared by software and cleared by hardware after a reset. They select the clock frequency of the counter. The change be- comes effective after an overflow. Note 1: PWM mode is not available at this fre- quency. Note 2: ATICR counter may return inaccurate re- sults when read. It is therefore not recommended to use Input Capture mode at this frequency. Bit 2 = OVF Overflow Flag. This bit is set by hardware and cleared by software by reading the TCSR register. It indicates the tran- sition of the counter from FFh to ATR value. 0: No counter overflow occurred 1: Counter overflow occurred Bit 1 = OVFIE Overflow Interrupt Enable. This bit is read/write by software and cleared by hardware after a reset. 0: OVF interrupt disabled. 1: OVF interrupt enabled. Bit 0 = CMPIE Compare Interrupt Enable. This bit is read/write by software and cleared by hardware after a reset. It can be used to mask the interrupt generated when the CMPF bit is set. 0: CMPF interrupt disabled. 1: CMPF interrupt enabled. COUNTER REGISTER HIGH (CNTRH) Read only Reset Value: 0000 0000 (000h) COUNTER REGISTER LOW (CNTRL) Read only Reset Value: 0000 0000 (000h) Bits 15:12 = Reserved. Bits 11:0 = CNTR[11:0] Counter Value. This 12-bit register is read by software and cleared by hardware after a reset. The counter is incre- mented continuously as soon as a counter clok is selected. To obtain the 12-bit value, software should read the counter value in two consecutive read operations, LSB first. When a counter over- flow occurs, the counter restarts from the value specified in the ATR register. 76 0 0 ICF ICIE CK1 CK0 OVF OVFIE CMPIE Counter Clock Selection CK1 CK0 OFF 0 0 fLTIMER (1 ms timebase @ 8 MHz) 1) 01 fCPU 10 32 MHz 2) 11 15 8 0000 CNTR 11 CNTR 10 CNTR9 CNTR8 70 CNTR7 CNTR6 CNTR5 CNTR4 CNTR3 CNTR2 CNTR1 CNTR0 1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |