| 数据搜索系统,热门电子元器件搜索 |
|
M41T81S 数据表(PDF) 9 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M41T81S 数据表(HTML) 9 Page - STMicroelectronics |
|
9 / 31 page ![]() M41T81S Operation 9/31 2 Operation The M41T81S clock operates as a slave device on the serial bus. Access is obtained by implementing a start condition followed by the correct slave address (D0h). The 20 bytes contained in the device can then be accessed sequentially in the following order: 1. Tenths/Hundredths of a Second Register 2. Seconds Register 3. Minutes Register 4. Century/Hours Register 5. Day Register 6. Date Register 7. Month Register 8. Year Register 9. Calibration Register 10. Watchdog Register 11 - 15. Alarm Registers 16. Flags Register 17 - 19. Reserved 20. Square Wave Register The M41T81S clock continually monitors VCC for an out-of-tolerance condition. Should VCC fall below VPFD, the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from a an out-of-tolerance system. Once VCC falls below the switchover voltage (VSO), the device automatically switches over to the battery and powers down into an ultra-low current mode of operation to preserve battery life. If VBAT is less than VPFD, the device power is switched from VCC to VBAT when VCC drops below VBAT. If VBAT is greater than VPFD, the device power is switched from VCC to VBAT when VCC drops below VPFD. Upon power-up, the device switches from battery to VCC at VSO. When VCC rises above VPFD, it will recognize the inputs. For more information on Battery Storage Life refer to Application Note AN1012. 2-wire bus characteristics The bus is intended for communication between different ICs. It consists of two lines: a bi- directional data signal (SDA) and a clock signal (SCL). Both the SDA and SCL lines must be connected to a positive supply voltage via a pull-up resistor. The following protocol has been defined: ● Data transfer may be initiated only when the bus is not busy. ● During data transfer, the data line must remain stable whenever the clock line is High. ● Changes in the data line, while the clock line is High, will be interpreted as control signals. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |