| 数据搜索系统,热门电子元器件搜索 |
|
L6566B 数据表(PDF) 37 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6566B 数据表(HTML) 37 Page - STMicroelectronics |
|
37 / 51 page ![]() L6566B Application information 37/51 Equation 15 where TBLANK2 = 2 µs; this is also illustrated in the diagram of Figure 24. 5.12 Brownout protection Brownout protection is basically a not-latched device shutdown function activated when a condition of mains undervoltage is detected. There are several reasons why it may be desirable to shut down a converter during a brownout condition, which occurs when the mains voltage falls below the minimum specification of normal operation. Firstly, a brownout condition may cause overheating of the primary power section due to an excess of RMS current. Secondly, spurious restarts may occur during converter power down, hence causing the output voltage not to decay to zero monotonically. L6566B shutdown upon brownout is accomplished by means of an internal comparator, as shown in the block diagram of Figure 25 on page 38, which shows the basic usage. The inverting input of the comparator, available on the AC_OK pin (16), is supposed to sense a voltage proportional to the RMS (peak) mains voltage; the non-inverting input is internally referenced to 0.485 V with 35 mV hysteresis. If the voltage applied on the AC_OK pin before the device starts operating does not exceed 0.485 V or if it falls below 0.45 V while the device is running, the AC_FAIL signal goes high and the device shuts down, with the soft- start capacitor discharged and the gate-drive output low. Additionally, if the device has been latched off by some protection function (testified by Vcc oscillating between VccON and VccON - 0.5 V) the AC_OK voltage falling below 0.45 V clears the latch. This may allow a quicker restart as the input source is removed. While the brownout protection is active the start-up generator keeps on working but, being there no PWM activity, the Vcc voltage continuously oscillates between the start-up and the HV generator restart thresholds, as shown in the timing diagram of Figure 25. Figure 24. Maximum allowed duty cycle vs switching frequency for correct OVP detection 1 f T D sw 2 BLANK ≤ + 5 .10 4 1 .10 5 1.5 .10 5 2 .10 5 2.5.10 5 3 .10 5 3.5.10 5 4 .10 5 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.725 fsw [Hz] Dmax |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |