2 / 6 page ![]() STPS3L60/Q/U 2/6 Symbol Parameter Tests conditions Min. Typ. Max. Unit IR * Reverse leakage current Tj = 25°C VR =VRRM 150 µA Tj = 100°C 415 mA Tj = 125°C 14 30 VF * Forward voltage drop Tj = 25°C IF =3 A 0.62 V Tj = 100°C 0.53 0.61 Tj = 125°C 0.51 0.59 Tj = 25°C IF =6 A 0.79 Tj = 100°C 0.62 0.71 Tj = 125°C 0.6 0.69 Pulse test : * tp = 380 µs, δ <2% To evaluate the maximum conduction losses use the following equation: P=0.44xIF(AV) +0.05xIF 2 (RMS) STATIC ELECTRICAL CHARACTERISTICS Symbol Parameter Value Unit Rth(j-l) Junction to leads Lead length = 10 mm DO-201AD 20 °C/W SMB 20 DO-15 35 THERMAL RESISTANCES 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 0.0 0.5 1.0 1.5 2.0 2.5 T δ=tp/T tp δ = 0.05 δ = 0.1 δ = 0.2 δ = 0.5 δ = 1 P (W) F(AV) I (A) F(AV) Fig. 1: Average forward power dissipation versus average forward current. 0 25 50 75 100 125 150 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 T δ=tp/T tp I (A) F(AV) T (°C) amb R=R th(j-a) th(j-I) R =80°C/W th(j-a) Fig. 2-1: Average forward current versus ambient temperature ( δ = 0.5) (DO-201AD, SMB). |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|