43 / 61 page ![]() SECTION 5 TIMER OPERATION AND APPLICATIONS SUMMARY This section describes the programmable options available, capabilities, and restrictions that apply to the timer. Programming of the timer control register is outlined with several examples given. 5.1. TIMER OPERATION The TS68230 timer can provide several facilities needed by TS68000 operating systems. It can ge- nerate periodic interrupts, a square wave, or a single interrupt after a programmed time period. Also, it can be used for elapsed time measurement or as a device watchdog. The PI/T timer contains a 24-bit synchronous down counter that is loaded from three 8-bit counter pre- load registers. The 24-bit counter may be clocked by the output of a 5-bit (divide-by-32) prescaler or by an external timer input (TIN). If the prescaler is used, it may be clocked by the system clock (CLK pin) or by the TIN external input. The counter signals the oc- currence of an event primarily through zero detec- tion. (A zero is when the counter of the 24-bit timer is equal to zero). This sets the zero detect status (ZDS) bit in the timer status register. It may be checked by the processor or may be used to gene- rate a timer interrupt. The ZDS bit can be reset by writing a one to the timer status register in that bit po- sition independent of timer operation. The general operation of the timer is flexible and ea- sily programmable. The timer is fully configured and controlled by programming the 8-bit timer control re- gister (refer to 4.9 Timer Control Register (TCR) for additional information). It controls : 1) the choice between the port C operation and the timer opera- tion of three timer pins, 2) whether the counter is loa- ded from the counter preload register or rolls over when zero detect is reached, 3) the clock input, 4) whether the prescaler is used, and 5) whether the timer is enabled. 5.1.1. RUN/HALT DEFINITION. The overall opera- tion of the timer is described in terms of the run or halt states. The control of the current state is deter- mined by programming the timer control register. When in the halt state, all of the following occur : 1. The prior content of the counter is not altered and is reliably readable via the count registers. 2. The prescaler is forced to $1F whether or not it is used. 3. The ZDS status bit is forced to zero, regardless of the possible zero contents of the 24-bit coun- ter. The run state is characterized by : 1. The counter is clocked by the source program- med in the timer control register. 2. The counter is not reliably readable. 3. The prescaler is allowed to decrement if pro- grammed for use. 4. The ZDS status bit is set when the 24-bit counter transitions from $000001 to $000000. 5.1.2. TIMER RULES. The following is a set of rules that allow easy application of the timer. 1. Refer to 5.1.1. Run/Halt Definition. 2. When the RESET pin is asserted, all bits of the timer control register are cleared, configuring the dual function pins as port C inputs. 3. The contents of the counter preload registers and counter are not affected by the RESET pin. 4. The count registers provide a direct read data path from each portion of the 24-bit counter, but data written to their addresses is ignored. (This results in a normal bus cycle). These registers are readable at any time, but their contents are never latched. Unreliable data may be read when the timer is in the run state. 5. The counter preload registers are readable and writable at any time and this occurs inde- pendently of any timer operation. No protection mechanisms are provided against ill-timed writes. 6. The input frequency to the 24-bit counter from the TIN pin or prescaler output must be between zero and the input frequency at the CLK pin divided by eight, regardless of the configuration chosen. 7. For configurations in which the prescaler is used (with the CLK pin or TIN pin as an input), the contents of the counter preload register (CPR) is transferred to the counter the first time that the prescaler passes from $00 to $1F (rolls over) af- ter entering the run state. Thereafter, the counter decrements, rolls over, or is loaded from the counter preload register each time the prescaler rolls over. TS68230 43/61 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |