| 数据搜索系统,热门电子元器件搜索 |
|
TDF8599BTH 数据表(PDF) 29 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDF8599BTH 数据表(HTML) 29 Page - NXP Semiconductors |
|
29 / 54 page ![]() TDF8599B_1 © NXP B.V. 2009. All rights reserved. Product data sheet Rev. 01 — 29 July 2009 29 of 54 NXP Semiconductors TDF8599B I2C-bus controlled dual channel class-D power amplifier Diagnostic output THDclip total harmonic distortion clip detection level - 0.2 - % Vth(offset) threshold voltage for offset detection [2][3] 123V VOL LOW-level output voltage DIAG or CLIP pins activated; Io =1mA - - 0.3 V IL leakage current DIAG and CLIP pins; diagnostic not activated --50 µA Audio inputs; pins IN1N, IN1P, IN2N and IN2P Vi input voltage - 2.45 - V SVRR voltage and ACGND input bias voltage in Mute and Operating modes Vref reference voltage input ACGND pin 2 2.45 3 V half supply reference SVRR pin 6.9 7.2 7.5 V Amplifier outputs; pins OUT1N, OUT1P, OUT2N and OUT2P VO(offset) output offset voltage BTL; Mute mode - - 25 mV BTL; Operating mode [4][6] --70 mV Stabilizer output; pins VSTAB1 and VSTAB2 Vo output voltage stabilizer output in Mute mode and Operating mode 8 1012V Voltage protections V(prot) protection voltage undervoltage; amplifier is muted 6.8 7.2 8 V overvoltage; load dump protection is activated 26.2 27 - V VP that a POR occurs at 3 3.7 4.6 V Current protection IO(ocp) overcurrent protection output current current limiting concept 8 9.5 11 A Temperature protection Tprot protection temperature 155 - 160 °C Tact(th_fold) thermal foldback activation temperature gain = −1 dB 140 - 150 °C Tj(AV)(warn1) average junction temperature for pre-warning 1 IB2[D3] = 0; non-I2C-bus mode - 140 150 °C Tj(AV)(warn2) average junction temperature for pre-warning 2 IB2[D3] = 1 - 120 130 °C DC load detection levels: I2C-bus mode only[7] Zth(load) load detection threshold impedance for normal speaker load; DB1[D4] = 0; DB2[D4] = 0 --25 Ω Zth(open) open load detection threshold impedance DB1[D4] = 1; DB2[D4] = 1 350 - - Ω AC load detection levels: I2C-bus mode only Ith(o)det(load)AC AC load detection output threshold current 250 500 700 mA Table 19. Static characteristics …continued VP =VDDA = 14.4 V; fosc = 320 kHz; −40 °C < Tamb < +85 °C; unless otherwise specified. Symbol Parameter Conditions Min Typ Max Unit |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |