13 / 38 page ![]() © 2009 Microchip Technology Inc. DS22072B-page 13 MCP3425 5.0 USING THE MCP3425 DEVICE 5.1 Operating Modes The user operates the device by setting up the device configuration register using a write command (see Figure 5-2) and reads the conversion data using a read command (see Figure 5-3). The device operates in two modes: (a) Continuous Conversion Mode or (b) One- Shot Conversion Mode (single conversion). This mode selection is made by setting the O/C bit in the Configuration Register. Refer to Section 5.2 “Configuration Register” for more information. 5.1.1 CONTINUOUS CONVERSION MODE (O/C BIT = 1) The device performs a Continuous Conversion if the O/ C bit is set to logic “high”. Once the conversion is completed, RDY bit is toggled to ‘0’ and the result is placed at the output data register. The device immediately begins another conversion and overwrites the output data register with the most recent result. The device clears the data ready flag (RDY bit = 0) when the conversion is completed. The device sets the ready flag bit (RDY bit = 1), if the latest conversion result has been read by the Master. • When writing configuration register: - Setting RDY bit in continuous mode does not affect anything • When reading conversion data: - RDY bit = 0 means the latest conversion result is ready - RDY bit = 1 means the conversion result is not updated since the last reading. A new conversion is under processing and the RDY bit will be cleared when the new conversion result is ready 5.1.2 ONE-SHOT CONVERSION MODE (O/C BIT = 0) Once the One-Shot Conversion (single conversion) Mode is selected, the device performs only one conversion, updates the output data register, clears the data ready flag (RDY = 0), and then enters a low power standby mode. A new One-Shot Conversion is started again when the device receives a new write command with RDY = 1. • When writing configuration register: - The RDY bit needs to be set to begin a new conversion in one-shot mode • When reading conversion data: - RDY bit = 0 means the latest conversion result is ready - RDY bit = 1 means the conversion result is not updated since the last reading. A new conversion is under processing and the RDY bit will be cleared when the new conversion is done This One-Shot Conversion Mode is recommended for low power operating applications. During the low current standby mode, the device consumes less than 1 µA typical. For example, if the device converts only one time per second with 16 bit resolution, the total current draw is only about one fourth of the draws in continuous mode. In this example, the device consumes approximately 9.7 µA (= ~145 µA/15 SPS), if the device performs only one conversion per second (1 SPS) in 16-bit conversion mode with 3V power supply. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |