| 数据搜索系统,热门电子元器件搜索 |
|
MCP9804-E/MS 数据表(PDF) 18 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP9804-E/MS 数据表(HTML) 18 Page - Microchip Technology |
|
18 / 54 page ![]() MCP9804 DS22203A-page 18 © 2009 Microchip Technology Inc. 5.1.1 SENSOR CONFIGURATION REGISTER (CONFIG) The MCP9804 has a 16-bit Configuration register (CONFIG) that allows the user to set various functions for a robust temperature monitoring system. Bits 10 thru 0 are used to select Temperature Alert output hysteresis, device Shutdown or Low-Power mode, temperature boundary and critical temperature lock, and temperature Alert output enable/disable. In addition, Alert output condition (output set for TUPPER and TLOWER temperature boundary or TCRIT only), Alert output status and Alert output polarity and mode (Comparator Output or Interrupt Output mode) are user configurable. The temperature hysteresis bits 10 and 9 can be used to prevent output chatter when the ambient temperature gradually changes beyond the user-specified temperature boundary (see Section 5.2.2. The Continuous Conversion or Shutdown mode is selected using bit 8. In Shutdown mode, the band gap temperature sensor circuit stops converting temperature and the Ambient Temperature register (TA) holds the previous temperature data (see Section 5.2.1). Bits 7 and 6 are used to lock the user- specified boundaries TUPPER, TLOWER and TCRIT to prevent an accidental rewrite. The Lock bits are cleared by reseting power. Bits 5 thru 0 are used to configure the temperature Alert output pin. All functions are described in Register 5-2 (see Section 5.2.3). REGISTER 5-2: CONFIGURATION REGISTER (CONFIG) → ADDRESS ‘0000 0001’b U-0 U-0 U-0 U-0 U-0 R/W-0 R/W-0 R/W-0 —— — — — THYST SHDN bit 15 bit 8 R/W-0 R/W-0 R/W-0 R-0 R/W-0 R/W-0 R/W-0 R/W-0 Crit. Lock Win. Lock Int. Clear Alert Stat. Alert Cnt. Alert Sel. Alert Pol. Alert Mod. bit 7 bit 0 Legend: R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’ -n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown bit 15-11 Unimplemented: Read as ‘0’ bit 10-9 TUPPER and TLOWER Limit Hysteresis (THYST): 00 = 0°C (power-up default) 01 = 1.5°C 10 = 3.0°C 11 = 6.0°C (Refer to Section 5.2.3) This bit can not be altered when either of the lock bits are set (bit 6 and bit 7). This bit can be programmed in shutdown mode. bit 8 Shutdown Mode (SHDN): 0 = Continuous Conversion (power-up default) 1 = Shutdown (Low-Power mode) In shutdown, all power-consuming activities are disabled, though all registers can be written to or read. This bit cannot be set ‘1’ when either of the lock bits is set (bit 6 and bit 7). However, it can be cleared ‘0’ for Continuous Conversion while locked. (Refer to Section 5.2.1). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |