23 / 33 page ![]() AS5040 Data Sheet www.austriamicrosystems.com Revision 2.10 23 - 33 Figure 20: Typical Magnet and Magnetic Field Distribution N S Magnet axis Vertical field component (45…75mT) 0 360 Bv Vertical field component R1 concentric circle; radius 1.1mm R1 Magnet axis typ. 6mm diameter S N Physical Placement of the Magnet The best linearity can be achieved by placing the center of the magnet exactly over the defined center of the IC package as shown in Figure 21: Figure 21: Defined IC Center and Magnet Displacement Radius 1 Defined center 2.433 mm 2.433 mm 3.9 mm 3.9 mm Area of recommended maximum magnet misalignment Rd Magnet Placement The magnet’s center axis should be aligned within a displacement radius Rd of 0.25mm from the defined center of the IC with reference to the edge of pin #1 (see Figure 21). This radius includes the placement tolerance of the chip within the SSOP-16 package (+/- 0.235mm). The displacement radius Rd is 0.485mm with reference to the center of the chip (see section 13: Alignment Mode) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|