| 数据搜索系统,热门电子元器件搜索 |
|
AS5140HASST 数据表(PDF) 29 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS5140HASST 数据表(HTML) 29 Page - ams AG |
|
29 / 37 page ![]() www.austriamicrosystems.com/AS5140H Revision 1.4 29 - 37 AS5140H Data Sheet - D e t a i l e d D e s c r i p t i o n Figure 23. Example of Linearity Error Over 360º 7.12.2 Transition Noise Transition noise is defined as the jitter in the transition between two steps. Due to the nature of the measurement principle (Hall sensors + Preamplifier + ADC), there is always a certain degree of noise involved. This transition noise voltage results in an angular transition noise at the outputs. It is specified as 0.06 degrees rms (1 sigma) 1. This is the repeatability of an indicated angle at a given mechanical position. The transition noise has different implications on the type of output that is used: Absolute Output; SSI Interface: The transition noise of the absolute output can be reduced by the user by applying an averaging of read- ings. An averaging of 4 readings will reduce the transition noise by 50% = 0.03º rms (1 sigma). PWM Interface: If the PWM interface is used as an analog output by adding a low pass filter, the transition noise can be reduced by lower- ing the cutoff frequency of the filter. If the PWM interface is used as a digital interface with a counter at the receiving side, the transition noise may again be reduced by averaging of readings. Incremental Mode: In incremental mode, the transition noise influences the period, width and phase shift of the output signals A, B and Index. However, the algorithm used to generate the incremental outputs guarantees no missing or additional pulses even at high speeds (up to 10.000 rpm and higher). 7.12.3 High Speed Operation The AS5140H samples the angular value at a rate of 10.42k samples per second. Consequently, the incremental and the absolute outputs are updated each by 96µs. At a stationary position of the magnet, this sampling rate creates no additional error. Absolute Mode. With the given sampling rate of 10.4 kHz, the number of samples (n) per turn for a magnet rotating at high speed can be calculated by: n = (EQ 6) In practice, there is no upper speed limit. The only restriction is that there will be fewer samples per revolution as the speed increases. Regardless of the rotational speed, the absolute angular value is always sampled at the highest resolution of 10 bit. Likewise, for a given number of samples per revolution (n), the maximum speed can be calculated by: rpm = (EQ 7) 1. Statistically, 1 sigma represents 68.27% of readings; 3 sigma represents 99.73% of readings. -0.5 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 1 55 109 163 217 271 325 379 433 487 541 595 649 703 757 811 865 919 973 transition noise Err max Err min 60 rpm 96 μs ⋅ --------------------------- 60 n 96 μs ⋅ -------------------- |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |