12 / 16 page ![]() Si9993CS Vishay Siliconix S-60752–Rev. A, 05-Apr-99 FaxBack 408-970-5600, request 70653 12 www.siliconix.com REG5 (Spindle Command) to “00” state. Individual motor shutdown operation is also possible through the serial port. Refer to Table 2 for a complete description. Immediately after detection of the undervoltage condition, all spindle drivers are turned off while the VCM’s low-side drivers are turned on to stop the head from any previous movement. Additionally, all command resistors, except REG1, are reset. After a time delay, programmed by D5/D4 of REG1, the VCM’s retract circuitry is turned on. The spindle drivers remained off. The head is retracted toward the inside diameter of the disk, or (VCM+ - VCM-) is positive. The voltage clamp across the VCM, or the maximum head velocity, is limited by the stored value in D7/D6 of REG1. No programmable current clamp is available on Si9993CS. The minimum short-circuited VCM retract current is 120 mA. Refer to Figure 3 for a simplified schematic. The head retract time interval, or spindle brake delay time, is programmed via bit D3/D2 of REG1. After the time-out, the VCM drivers are turned off (tri-state) and all bits of REG1 except D1/D0 are reset. The state of the spindle motor low-side drivers are determined by D1/D0) of REG1. Depending on the motor and the number of disk platters, a spindle brake at high speed (BEMF voltage of 6 V or higher) may result in a high amount of energy dissipation in the LITTLE FOOT drivers. One solution to this problem is to use a ultra-low rDS(on) LITTLE FOOT device, such as Si4544, should the dissipation limit of the Si9942 be exceeded. In which case, D1/D0 or REG1 should be programmed for immediate brake. A lower cost solution, when feasible, is to allow the motor to spin down to a lower rpm before the low-side drivers are turned on to brake the motor. In such case, the motor speed threshold, which is sensed by measuring the motor BEMF via VCLAMP voltage, is programmed using D1/D0 of REG1. (Figure 4 shows a 3-V threshold being selected.) Also, as shown in Figure 4, once the spindle brake is on, an external pre-charged capacitor connected to the VTEST pin will be switched on to maintain the gate drive to the LITTLE FOOT drivers, even if VCLAMP drops down to zero. FIGURE 3. Simplified Retract Circuit FIGURE 4. Simplified Spindle Brake Circuit |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |