12 / 30 page ![]() ADM1031 http://onsemi.com 12 speed. Bit 1 (Fan Fault) is set whenever a fan tach failure is detected. Once cleared, it reasserts on subsequent fan tach failures. Bit 2 and Bit 3 of Status Register 1 and Status Register 2 are the Remote 1 and Remote 2 Temperature High and Low status bits. Exceeding the high or low temperature limits for the external channel sets these status bits. Reading the status register clears these bits. However, these bits are reasserted if the out−of−limit condition still exists on the next monitoring cycle. Bit 6 and Bit 7 are the Local Temperature High and Low status bits. These behave exactly the same as the Remote Temperature High and Low status bits. Bit 4 of Status Register 1 indicates that the Remote Temperature THERM limit has been exceeded. This bit gets cleared on a read of Status Register 1 (see Figure 20). Bit 5 indicates a remote diode error. This bit is a 1 if a short or open is detected on the remote temperature channel on powerup. If this bit is set to 1 on powerup, it cannot be cleared. Bit 6 of Status Register 2 (0 ×03) indicates that the Local THERM limit has been exceeded. This bit is cleared on a read of Status Register 2. Bit 7 indicates that THERM has been pulled low as an input. This bit can also be cleared on a read of Status Register 2. Figure 20. Operation of THERM and INT Signals 5° INT REARMED STATUS REG. READ TEMP THERM LIMIT THERM INT Figure 20 shows the interaction between INT and THERM. Once a critical temperature THERM limit is exceeded, both INT and THERM assert low. Reading the status registers clears the interrupt and the INT pin goes high. However, the THERM pin remains asserted until the measured temperature falls 5 °C below the exceeded THERM limit. This feature can be used to CPU throttle or drive a fan full speed for maximum cooling. Note that the INT pin for that interrupt source is not rearmed until the temperature has fallen below the THERM limit –5 °C. This prevents unnecessary interrupts from tying up valuable CPU resources. Fan Control Modes of Operation The ADM1031 has four different modes of operation. These modes determine the behavior of the system. 1. Automatic Fan Speed Control Mode. 2. Filtered Automatic Fan Speed Control Mode. 3. PWM Duty Cycle Select Mode (directly sets fan speed under software control). 4. RPM Feedback Mode. Automatic Fan Speed Control The ADM1031 has a local temperature channel and two remote temperature channels, which can be connected to an on−chip diode−connected transistor on a CPU. These three temperature channels can be used as the basis for an automatic fan speed control loop to drive fans using pulse width modulation (PWM). How Does the Control Loop Work? The automatic fan speed control loop is shown in Figure 21. Figure 21. Automatic Fan Speed Control Loop MAX FAN SPEED MIN TEMPERATURE TMIN TMAX = TMIN + TRANGE SPIN−UP FOR SECONDS TMIN is the temperature at which the fan should switch on and run at minimum speed. The fan only turns on once the temperature being measured rises above the TMIN value programmed. The fan spins up for a predetermined time (default = 2 seconds). See the Fan Spin−Up section for more details. TRANGE is the temperature range over which the ADM1031 automatically adjusts the fan speed. As the temperature increases beyond TMIN, the PWM_OUT duty cycle increases accordingly. The TRANGE parameter actually defines the fan speed vs. temperature slope of the control loop. TMAX is the temperature at which the fan is at its maximum speed. At this temperature, the PWM duty cycle driving the fan is 100%. TMAX is given by TMIN + TRANGE. Since this parameter is the sum of the TMIN and TRANGE parameters, it does not need to be programmed into a register on−chip. A hysteresis value of 5 °C is included in the control loop to prevent the fan continuously switching on and off if the temperature is close to TMIN. The fan continues to run until the temperature drops 5 °C below TMIN. Figure 22 shows the different control slopes determined by the TRANGE value chosen, and programmed into the ADM1031. TMIN is set to 0°C to start all slopes from the same point. The figure shows how changing the TRANGE value affects the PWM duty cycle vs. temperature slope. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |