15 / 30 page ![]() ADM1031 http://onsemi.com 15 Table 7. Programming PWM Duty Cycle Decimal Value PWM Duty Cycle 00 0% 01 7% 02 14% 03 20% 04 27% 05 33% (Default) 06 40% 07 47% 08 53% 09 60% 10 (0×0A) 67% 11 (0×0B) 73% 12 (0×0C) 80% 13 (0×0D) 87% 14 (0×0E) 93% 15 (0×0F) 100% The temperature at which the fan runs full−speed (100% duty cycle) is given by: TMAX = TMIN + ((Max DC – Min DC) × TRANGE/10) where: TMAX = Temperature at which fan runs full−speed. TMIN = Temperature at which fan turns on. Max DC = Maximum duty cycle (100%) = 15 decimal. Min DC = Duty cycle at TMIN, programmed in to fan speed configuration register (default = 33% = 5 decimal). TRANGE = PWM duty cycle vs. temperature slope. Example 1 TMIN = 0°C, TRANGE = 40°C Min DC = 53% = 8 decimal (Table 7) Calculate TMAX. TMAX = TMIN + ((Max DC − Min DC) × TRANGE/10) TMAX = 0 + ((100% DC − 53% DC) × 40/10) TMAX = 0 + ((15 − 8) × 4) = 28 TMAX = 28°C (as seen on Slope 2 of Figure 26) Example 2 TMIN = 0°C, TRANGE = 40°C Min DC = 73% = 11 decimal (Table 7) Calculate TMAX. TMAX = TMIN + ((Max DC – Min DC) × TRANGE/10) TMAX = 0 + ((100% DC – 73% DC) × 40/10) TMAX = 0 + ((15 – 11) × 4) = 16 TMAX = 16°C (as seen on Slope 3 of Figure 26) Example 3 TMIN = 0°C, TRANGE = 40°C Min DC = 33% = 5 decimal (Table 7) Calculate TMAX. TMAX = TMIN + ((Max DC – Min DC) × TRANGE/10) TMAX = 0 + ((100% DC – 33% DC) × 40/10) TMAX = 0 + ((15 – 5) × 4) = 40 TMAX = 40°C (as seen on Slope 1 of Figure 26) In this case, since the minimum duty cycle is the default 33%, the equation for TMAX reduces to: TMAX = TMIN + ((Max DC – Min DC) × TRANGE/10) TMAX = TMIN + ((15 – 5) × TRANGE/10) TMAX = TMIN + (10 × TRANGE/10) TMAX = TMIN + TRANGE Relevant Registers for Automatic Fan Speed Control Mode Register 0y00 Configuration Register 1 <7> Logic 1 selects automatic fan speed control, Logic 0 selects software control (Default = 1). <6:5> 00 = Remote Temp 1 controls Fan 1, Remote Temp 2 controls Fan 2. 01 = Remote Temp 1 controls Fan 1 and Fan 2 10 = Remote Temp 2 controls Fan 1 and Fan 2 11 = Fastest Calculated Speed controls Fan 1 and 2 Register 0y20, 0y21 Fan Characteristics Registers 1, 2 <2:0> Fan X Spin−Up Time. 000 = 200 ms 001 = 400 ms 010 = 600 ms 011 = 800 ms 100 = 1 sec 101 = 2 sec (Default) 110 = 4 sec 111 = 8 sec <5:3> PWM Frequency Driving the Fan. 000 = 11.7 Hz 001 = 15.6 Hz 010 = 23.4 Hz 011 = 31.25 Hz (Default) 100 = 37.5 Hz 101 = 46.9 Hz 110 = 62.5 Hz 111 = 93.5 Hz <7:6> Speed Range N; defines the lowest fan speed that can be measured by the device. 00 = 1: Lowest Speed = 2647 RPM 01 = 2: Lowest Speed = 1324 RPM 10 = 4: Lowest Speed = 662 RPM 11 = 8: Lowest Speed = 331 RPM Register 0y22 Fan Speed Configuration Register <3:0> Min Speed: This nibble contains the speed at which the fan runs when the temperature is at TMIN. The default is 0 ×05, meaning that the fan runs at 33% duty cycle when the temperature is at TMIN. <7:4> Min Speed: Determines the minimum PWM cycle for Fan 2 in automatic fan speed control mode. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |