部件名 SA2007P
功能描述  Programmable Single Phase Energy Metering IC with Tamper Detection
PDF  12 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  SAMES [Sames]
网页  http://www.sames.co.za
标志 SAMES - Sames

SA2007P 数据表(HTML) 8 Page - Sames

Back Button SA2007P Datasheet HTML 4Page - Sames SA2007P Datasheet HTML 5Page - Sames SA2007P Datasheet HTML 6Page - Sames SA2007P Datasheet HTML 7Page - Sames SA2007P Datasheet HTML 8Page - Sames SA2007P Datasheet HTML 9Page - Sames SA2007P Datasheet HTML 10Page - Sames SA2007P Datasheet HTML 11Page - Sames SA2007P Datasheet HTML 12Page - Sames  
Zoom Inzoom in Zoom Outzoom out
 8 / 12 page
background image
sames
sames
SA2007P
8/12
http://www.sames.co.za
LED Pulse-rate (CLED)
Two bits of byte D22 allow for the selection of 3 different LED
Pulse-rate as follows.
Refer to LED output section for details on the LED pulse width.
Counter Pulse-Width (CPW)
The pulse with for the mechanical counter driver output is
selectable to accommodate various step-motor and impulse-
counter requirements. Bit 6 from byte D24 selects the pulse
rate as follows:
Counter Resolution (CRES)
Bit 1 and 0 from byte D24 allow for the selection of 3 different
counter resolutions. Note that one energy pulse is represented
by a MOP pulse followed by a MON pulse.
D24[1]
D24[0]
Counter Resolution
0
1
-
0
0
1
1 p/KWh
10 p/KWh
100 p/KWh
Channel Select Mode (CS)
For calibration purposes, the source for the energy metering
may be selected from a specific channel. The ELT-indication is
not influenced, but the metering is taken from the selected
channel only. For normal operation, the channel select mode is
set to automatic mode so that the larger of the two channels is
used for energy measurement. Bits 3 and 2 of byte D26 sets
the channel select mode as follows:
Earth Leak Compensation (NE)
Earth leakage in domestic wiring systems could result in
tamper detection at low current levels. The SA2007P caters for
these conditions, by taking possible earth leakage into account
when comparing the power consumption in live and neutral.
The value for the permissible earth leakage is usually around
30mA. It has to be adjusted according to the rated meter
condition and allows for derivations from the 30mA value. The
actual value of the leak current can be calculated from the
following formula:
Ileak = Rated current x Ne
Ileak is the earth leakage current in mA used for correction. this
value is subtracted from the difference measured between live
and neutral power.
Ne is made up of bits 1 and 2 of byte D26 and can be set as
follows:
D26[3]
D26[2]
Metering Source
-
1
0
0
1
1
Automatic, channel 1 or 2 whichever
shows higher consumption
Channel 1
Channel 2
D22[1]
D22[0]
Calibrated LED - Output
0
0
1
0
1
-
6400 p/KWh
3200 p/KWh
1252 pulses/second @rated for
fast calibration
D24[6]
Counter Pulse-Width
0
1
71ms
142ms
D26[1]
D26[0]
Ne factor
0
0
1
0
1
-
0.15
0.076
0.038
PRELIMINARY



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com