SA2007P 数据表(HTML) 8 Page - Sames |
|
8 / 12 page ![]() sames sames SA2007P 8/12 http://www.sames.co.za LED Pulse-rate (CLED) Two bits of byte D22 allow for the selection of 3 different LED Pulse-rate as follows. Refer to LED output section for details on the LED pulse width. Counter Pulse-Width (CPW) The pulse with for the mechanical counter driver output is selectable to accommodate various step-motor and impulse- counter requirements. Bit 6 from byte D24 selects the pulse rate as follows: Counter Resolution (CRES) Bit 1 and 0 from byte D24 allow for the selection of 3 different counter resolutions. Note that one energy pulse is represented by a MOP pulse followed by a MON pulse. D24[1] D24[0] Counter Resolution 0 1 - 0 0 1 1 p/KWh 10 p/KWh 100 p/KWh Channel Select Mode (CS) For calibration purposes, the source for the energy metering may be selected from a specific channel. The ELT-indication is not influenced, but the metering is taken from the selected channel only. For normal operation, the channel select mode is set to automatic mode so that the larger of the two channels is used for energy measurement. Bits 3 and 2 of byte D26 sets the channel select mode as follows: Earth Leak Compensation (NE) Earth leakage in domestic wiring systems could result in tamper detection at low current levels. The SA2007P caters for these conditions, by taking possible earth leakage into account when comparing the power consumption in live and neutral. The value for the permissible earth leakage is usually around 30mA. It has to be adjusted according to the rated meter condition and allows for derivations from the 30mA value. The actual value of the leak current can be calculated from the following formula: Ileak = Rated current x Ne Ileak is the earth leakage current in mA used for correction. this value is subtracted from the difference measured between live and neutral power. Ne is made up of bits 1 and 2 of byte D26 and can be set as follows: D26[3] D26[2] Metering Source - 1 0 0 1 1 Automatic, channel 1 or 2 whichever shows higher consumption Channel 1 Channel 2 D22[1] D22[0] Calibrated LED - Output 0 0 1 0 1 - 6400 p/KWh 3200 p/KWh 1252 pulses/second @rated for fast calibration D24[6] Counter Pulse-Width 0 1 71ms 142ms D26[1] D26[0] Ne factor 0 0 1 0 1 - 0.15 0.076 0.038 PRELIMINARY |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |