| 数据搜索系统,热门电子元器件搜索 |
|
SA2007P 数据表(PDF) 3 Page - Sames |
|
|
|||||||||||||||||||||||||||||
SA2007P 数据表(HTML) 3 Page - Sames |
|
3 / 12 page ![]() 3/12 sames sames SA2007P http://www.sames.co.za Figure 2: Pin connections: Package: DIP-20, SOIC-20 Part Number SA2007PPA SA2007PSA Package DIP-20 SOIC-20 ORDERING INFORMATION PIN DESCRIPTION Analog Ground. The voltage to this pin should be mid-way between V and V . DD SS Positive supply voltage. The voltage to this pin is typically +2.5V if a shunt resistor is used for current sensing or in the case of a current transformer a +5V supply can be applied. GND V DD Designation Description PIN 20 8 Negative supply voltage. The voltage to this pin is typically -2.5V if a shunt resistor is used for current sensing or in the case of a current transformer a 0V supply can be applied. V SS 14 The current into the A/D converter should be set at 14µA at nominal mains voltage. The voltage RMS sense input saturates at an input current of ±25µA peak. 19 IVP Inputs for current sensor - channel 1 and channel 2. The shunt resistor voltage from each channel is converted to a current of 16µA at rated conditions. The current sense input saturates at an RMS input current of ±25µA peak. 1, 2, 3, 4 IIN1, IIP1 IIN2, IIP2 This pin provides the connection for the reference current setting resistor. A 24kW resistor connected to V sets the optimum operating condition. SS 5 VREF Serial clock output. This output is used to strobe data from the external EEPROM. 6 SCL Serial data. Send and receive data from an external EEPROM. 7 SDA Motor pulse outputs. These outputs can be used to drive an impulse counter or stepper motor directly. 9, 12 MON, MOP Calibration LED output. Refer to section Led Output (LED) for the pulse rate output options. 13 LED Configuration reload input. A falling edge will trigger a register reload from the external EEPROM. 15 RLOAD Current channel select output. This output indicates which channel is been used for kWh metering. 16 SEL1 Earth loop tamper output. This output indicates an earth loop tamper condition. 17 ELT Direction output. This output indicates the energy flow direction 18 DIRO Test input. Connect to V for normal operation. SS 10, 11 TEST, TCLK DR-01595 1 IIN1 GND SEL1 IIP1 IVP RLOAD IIN2 DIRO VSS IIP2 VREF SCL SDA VDD ELT LED MOP TCLK TEST MON 2 3 4 5 6 15 14 13 12 11 10 9 8 7 16 17 18 19 20 PRELIMINARY |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |