| 数据搜索系统,热门电子元器件搜索 |
|
ACS411CS 数据表(PDF) 8 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
ACS411CS 数据表(HTML) 8 Page - Semtech Corporation |
|
8 / 43 page ![]() 8 ACS411CS PRE-RELEASE Issue 6.0 July 1999. Diagnostic modes (main channel) The ACS4110 has four diagnostic/configuration modes implemented for the main channels, configured by CM(3:1). The following diagnostic / configuration modes are implemented for the main channels: - full duplex - full duplex slave - full duplex master - remote loop-back - local loop-back The modes are selectable via CM(3:1) either directly via pins, via the microprocessor interface or via remote control setup. All modes remote loop-back and local loop-back are selectable individually for each channel via the microprocessor interface. Table 5. shows the selection of diagnostic modes and configurations. CM(3:1) Diagnostic Mode/Configuration 111 local loop-back initiated from far end (remote setup only) 110 remote loop-back initiated from far end 101 local loop-back 100 remote loop-back 011 full duplex master 010 full duplex slave 001 full duplex slave/remote full duplex (remote setup only) 000 full duplex Table 5: Selection of diagnostic modes In remote setup (ENRSB=0), the far-end device will be setup complementary to the near-end device (control device) according to the Table 6. CM(3:1) Near End initiate Far End initiate (Control device) (Remote control device) 111 full duplex local loop-back 110 * remote loop-back 101 local loop-back full duplex 100 remote loop-back * 011 full-fuplex master full-duplex slave 010 full-duplex slave full-duplex master 001 full-duplex slave full-duplex 000 full duplex full duplex Table 6: Selection of diagnostic modes * Remote Loop-back Detect. For a remote loop-back initiated from the far end device, CM(3:1)=110, the initiating end transmitting and receiving the data will be setup as full duplex (see Figure:1). For remote loop-back, CM(3:1)=100, the remote loopback is initiated from the near end. In both cases, the data that is looped back will be the data applied to the near end device (see Figure:1). All modes are selectable via CM(3:1) either directly via pins or via the microprocessor interface. All the diagnostic modes, including remote loop-back and local loop-back are selectable individually for each main and maintenance channel via the microprocessor interface. Full-Duplex In the full-duplex configuration, the RCLK clock of both devices track the average frequency of the corresponding TCLK clock of the opposite end of the link. The receiving Digital-Phase-Lock Loop (DPLL) system makes periodic adjustments to the RCLK clock to ensure that the average frequency is exactly the same as the far-end TCLK clock. In summary, each TCLK is an independent master clock and each RCLK a slave of the far-end TCLK clock. The relationship between TmCLK and RmCLK are treated similarly. Full-Duplex Slave In slave mode, the TCLK and RCLK clock is derived from the TCLK clock of the far-end modem, such that their average frequencies are identical. Clearly, it is essential that only one modem within a communicating pair is configured in slave mode. The CKC pin should be forced to GND, so that TCLK is always configured as an output. The relationship between TmCLK and RmCLK are treated similarly. The CKM pin should be forced to GND, so that TmCLK is always configured as an output. Full-Duplex Master In master mode, the local RCLK clock is internally generated from the local TCLK clock. The local TCLK clock may be internally or externally generated. Master mode is only valid if the far-end device is configured in slave mode or if the far-end TCLK clock is derived from the far-end RCLK clock. Only one modem within a communicating pair may be configured as a master. The relationship between TmCLK and RmCLK are treated similarly. Local Loopback In local loopback mode, TPN and TmD data is looped back inside the near-end modem and is output at its own RPN and RmD outputs. Data received from the far-end device is ignored, except to maintain lock. If concurrent requests occur for local and remote loopback, local loopback is selected. The local loopback diagnostic mode is used to test data flow up to, and back from, the local ACS4110 and does not test the integrity of the link itself. Therefore, local loopback operates independently of synchronisation with a second modem (i.e. DCD may be High or Low). The local |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |