29 / 69 page ![]() L6472 Functional description Doc ID 022729 Rev 1 29/69 6.10 Undervoltage lockout (UVLO) The L6472 provides motor supply UVLO protection. When the motor supply voltage falls below the VSthOff threshold voltage, the STATUS register UVLO flag is forced low. When a GetStatus command is sent to the IC, and the undervoltage condition expires, the UVLO flag is released (see Section 9.1.19 and 9.2.20). The undervoltage condition expires when the motor supply voltage goes over the VSthOn threshold voltage. When the device is in the undervoltage condition, no motion command can be performed. The UVLO flag is forced low by logic reset (power-up included) even if no UVLO condition is present. 6.11 Thermal warning and thermal shutdown An internal sensor allows the L6472 to detect when the device internal temperature exceeds a thermal warning or an overtemperature threshold. When the thermal warning threshold (Tj(WRN)) is reached, the TH_WRN bit in the STATUS register is forced low (see Section 9.1.19) until the temperature decreases below Tj(WRN) and a GetStatus command is sent to the IC (see Section 9.1.19 and 9.2.20). When the thermal shutdown threshold (Tj(OFF)) is reached, the device goes into the thermal shutdown condition: the TH_SD bit in the STATUS register is forced low, the power bridges are disabled bridges in high-impedance state and the HiZ bit in the STATUS register is raised (see Section 9.1.19). The thermal shutdown condition only expires when the temperature goes below the thermal warning threshold (Tj(WRN)). On exiting the thermal shutdown condition, the bridges are still disabled (HiZ flag high); whichever motion command makes the device exit from High Z state (HardStop and SoftStop included). 6.12 Reset and standby The device can be reset and put into standby mode through a dedicated pin. When the STBY\RST pin is driven low, the bridges are left open (High Z state), the internal charge pump is stopped, the SPI interface and control logic are disabled, and the internal 3 V voltage regulator maximum output current is reduced to IREG,STBY; as a result, the L6472 heavily reduces the power consumption. At the same time the register values are reset to default and all protection functions are disabled. STBY\RST input must be forced low at least for tSTBY,min, in order to ensure the complete switch to standby mode. On exiting standby mode, as well as for IC power-up, a delay of up to tlogicwu must be given before applying a new command to allow proper oscillator and logic startup and a delay of up to tcpwu must be given to allow the charge pump startup. On exiting standby mode the bridges are disabled (HiZ flag high) and whichever motion command causes the device to exit High Z state (HardStop and SoftStop included). Attention: It is not recommended to reset the device when outputs are active. The device should be switched to high-impedance state before being reset. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |