| 数据搜索系统,热门电子元器件搜索 |
|
TMP100MDBVREP 数据表(PDF) 8 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMP100MDBVREP 数据表(HTML) 8 Page - Texas Instruments |
|
8 / 22 page ![]() TMP100−EP, TMP101−EP DIGITAL TEMPERATURE SENSOR WITH I2C INTERFACE SGLS254A − JULY 2005 - REVISED APRIL 2010 8 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 APPLICATION INFORMATION fault queue (F1/F0) A fault condition occurs when the measured temperature exceeds the limits set in the THIGH and TLOW registers. Additionally, the number of fault conditions required to generate an alert may be programmed using the fault queue. The fault queue is provided to prevent a false alert due to environmental noise and requires consecutive fault measurements to trigger the alert function. Table 7 defines the number of measured faults that may be programmed to trigger an alert condition. F1 F0 CONSECUTIVE FAULTS 0 0 1 0 1 2 1 0 4 1 1 6 Table 7. Fault Settings of the TMP100 and TMP101 converter resolution (R1/R0) The converter resolution bits control the resolution of the internal analog-to-digital (A/D) converter. This allows the user to maximize efficiency by programming for higher resolution or faster conversion time. Table 8 identifies the resolution bits and relationship between resolution and conversion time. R1 R0 RESOLUTION CONVERSION TIME (Typical) 0 0 9 Bits (0.5 °C) 40 ms 0 1 10 Bits (0.25 °C) 80 ms 1 0 11 Bits (0.125 °C) 160 ms 1 1 12 Bits (0.0625 °C) 320 ms Table 8. Resolution of the TMP100 os/alert (OS) The TMP100 and TMP101 feature a one-shot temperature measurement mode. When the device is in shutdown mode, writing a 1 to the OS/ALERT bit starts a single temperature conversion. The device returns to the shutdown state at the completion of the single conversion. This is useful to reduce power consumption in the TMP100 and TMP101 when continuous monitoring of temperature is not required. Reading the OS/ALERT bit provides information about the comparator mode status. The state of the POL bit will invert the polarity of data returned from the OS/ALERT bit. For POL = 0, the OS/ALERT reads as 1 until the temperature equals or exceeds THIGH for the programmed number of consecutive faults, causing the OS/ALERT bit to read as 0. The OS/ALERT bit continues to read as 0 until the temperature falls below TLOW for the programmed number of consecutive faults when it again reads as 1. The status of the TM bit does not affect the status of the OS/ALERT bit. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |