| 数据搜索系统,热门电子元器件搜索 |
|
L6480 数据表(PDF) 64 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6480 数据表(HTML) 64 Page - STMicroelectronics |
|
64 / 73 page ![]() Programming manual L6480 64/73 Doc ID 023278 Rev 3 command argument and can by changed by a new StepClock command without exiting Step-clock mode. Events that cause bridges to be forced into high impedance state (overtemperature, overcurrent, etc.) do not cause the device to leave Step-clock mode. The StepClock command does not force the BUSY flag low. This command can only be given when the motor is stopped. If a motion is in progress, the motor should be stopped and it is then possible to send a StepClock command. Any attempt to perform a StepClock command when the motor is running causes the command to be ignored and the NOTPERF_CMD flag to rise (Section 9.1.24). 9.2.7 Move (DIR, N_STEP) The move command produces a motion of N_STEP microsteps; the direction is selected by the DIR bit ('1' forward or '0' reverse). The N_STEP value is always in agreement with the selected step mode; the parameter value unit is equal to the selected step mode (full, half, quarter, etc.). This command keeps the BUSY flag low until the target number of steps is performed. This command can only be performed when the motor is stopped. If a motion is in progress the motor must be stopped and it is then possible to perform a move command. Any attempt to perform a move command when the motor is running causes the command to be ignored and the NOTPERF_CMD flag to rise (Section 9.1.24). 9.2.8 GoTo (ABS_POS) The GoTo command produces a motion to ABS_POS absolute position through the shortest path. The ABS_POS value is always in agreement with the selected step mode; the parameter value unit is equal to the selected step mode (full, half, quarter, etc.). The GoTo command keeps the BUSY flag low until the target position is reached. Table 54. Move command structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 01 00 00 0 DIR from host X X N_STEP (Byte 2) from host N_STEP (Byte 1) from host N_STEP (Byte 0) from host Table 55. GoTo command structure Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 1 1 0 00 00 from host X X ABS_POS (Byte 2) from host ABS_POS (Byte 1) from host ABS_POS (Byte 0) from host |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |