| 数据搜索系统,热门电子元器件搜索 |
|
AD7476SRT-R2 数据表(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7476SRT-R2 数据表(HTML) 12 Page - Analog Devices |
|
12 / 20 page ![]() REV. D –12– AD7476/AD7477/AD7478 INPUT FREQUENCY – Hz –50 10k –55 –60 –65 –70 –75 100k 1M –80 –85 –90 VDD = 2.35V VDD = 2.7V VDD = 5.25V VDD = 4.75V VDD = 3.6V Figure 9. THD vs. Analog Input Frequency, fS = 993 kSPS INPUT FREQUENCY – Hz –72 10k –74 –76 –78 –80 100k 1M –82 –84 VDD = 2.35V VDD = 2.7V VDD = 5.25V VDD = 4.75V VDD = 3.6V Figure 10. THD vs. Analog Input Frequency, fS = 605 kSPS Digital Inputs The digital inputs applied to the AD7476/AD7477/AD7478 are not limited by the maximum ratings that limit the analog inputs. Instead, the digital inputs applied can go to 7 V and are not restricted by the VDD + 0.3 V limit as on the analog inputs. For example, if the AD7476/AD7477/AD7478 were operated with a VDD of 3 V, then 5 V logic levels could be used on the digital inputs. However, it is important to note that the data output on SDATA will still have 3 V logic levels when VDD = 3 V. Another advantage of SCLK and CS not being restricted by the V DD + 0.3 V limit is the fact that power supply sequencing issues are avoided. If CS or SCLK is applied before V DD, there is no risk of latch-up as there would be on the analog inputs if a signal greater than 0.3 V was applied prior to VDD. MODES OF OPERATION The mode of operation of the AD7476/AD7477/AD7478 is selected by controlling the (logic) state of the CS signal during a conversion. There are two possible modes of operation, Normal mode and Power-Down mode. The point at which CS is pulled high after the conversion has been initiated will determine whether or not the AD7476/AD7477/AD7478 will enter Power-Down mode. Similarly, if already in power-down, CS can control whether the device will return to normal operation or remain in power-down. These modes of operation are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for different application requirements. Normal Mode This mode is intended for fastest throughput rate performance, as the user does not have to worry about any power-up times with the AD7476/AD7477/AD7478 remaining fully powered all the time. Figure 11 shows the general diagram of the operation of the AD7476/AD7477/AD7478 in this mode. The conversion is initiated on the falling edge of CS as described in the Serial Interface section. To ensure the part remains fully powered up at all times, CS must remain low until at least 10 SCLK falling edges have elapsed after the falling edge of CS. If CS is brought high any time after the tenth SCLK falling edge, but before the sixteenth SCLK falling edge, the part will remain powered up but the conversion will be terminated and SDATA will go back into three-state. Sixteen serial clock cycles are required to complete the conversion and access the complete 4 LEADING ZEROS + CONVERSION RESULT CS SCLK SDATA 1 10 16 Figure 11. Normal Mode Operation 1 10 16 2 THREE-STATE CS SCLK SDATA Figure 12. Entering Power-Down Mode |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |