8 / 49 page ![]() Aeroflex Circuit Technology SCD3492 REV B 6/26/01 Plainview NY (516) 694-6700 8 subaddress is busy but others are ready. This option will prove useful when an RT is interfacing with multiple subsystems. Use of the Service Request Status Bit The Service Request bit is used by the subsystem to indicate to the Bus Controller that an asynchronous service is requested. The timing of the setting of this bit is the same as the Busy bit and is shown in Figures 14 and 20. Use of SERVREQ has no effect on the RT apart from setting the Service Request bit. It should be noted that certain mode commands require that the last status word be transmitted by the RT instead of the current one, and therefore a currently set status bit will not be seen by the Bus Controller. Therefore the user is advised to hold SERVREQ low until the requested service takes place. Use of the Subsystem Status Bit This status bit is used by the RT to indicate a subsystem fault condition. If the subsystem sets SSERR low at any time, the subsystem fault condition in the RT will be set, and the Subsystem Flag status bit will subsequently be set. The fault condition will also be set if a handshaking failure takes place during a data transfer to or from the subsystem. The fault condition is cleared on power-up or by a Reset mode command. Dynamic Bus Control Acceptance Status Bit DBCACC, when set true, enables an RT to configure itself into a Bus Controller, if the subsystem has the capability, by allowing DBCREQ to pulse true and BIT TIME 18 to be set in the status response. If Dynamic Bus Control is not required then DBCACC must be tied high. DBCACC tied high inhibits DBCREQ and clears BIT TIME 18 in the status response. OPTIONAL STATUS WORD CONTROL Message Error Bit The ACT3492 monitors all receptions for errors and sets the Message Error Bit as prescribed in MIL-STD-1553B. The subsystem designer may, however, exercise the option of monitoring for illegal commands and forcing the Message Error Bit to be set. The word count and subaddress lines for the current command are valid when INCMD goes low. The subsystem must then determine whether or not the word count or subaddress is to be considered illegal by the RT. If either of them is considered illegal, the subsystem must produce a positive-going pulse called MEREQ. The positive-going edge of MEREQ must occur within 500 nSec of the falling edge of INCMD . Subsystem Flag and Terminal Flag Bits The conditions that cause the Subsystem Flag and Terminal Flag Bits in the Status Word to be reset may be controlled by the subsystem using the ENABLE, BIT DECODE, NEXT STATUS, and STATUS UPDATE inputs. If ENABLE is inactive (high), then the Terminal Flag and Subsystem Flag behavior is the same as described below: (i.e. the other three option lines are disabled). Subsystem Flag Bit This bit is reset to logic zero by a power up initialization or the servicing of a legal mode command to reset the remote terminal (code 01000). This bit shall be set in the current status register if the subsystem error line, SSERR, from the subsystem ever goes active low. This bit shall also be set if an RT/subsystem handshaking failure occurs. This bit, once set, shall be repeatedly set until the detected error condition is known to be no longer present. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |