| 数据搜索系统,热门电子元器件搜索 |
|
ADL5303ACPZ-R7 数据表(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADL5303ACPZ-R7 数据表(HTML) 18 Page - Analog Devices |
|
18 / 24 page ![]() ADL5303 Data Sheet Rev. 0 | Page 18 of 24 EVALUATION BOARD An evaluation board is available for the ADL5303, the sche- matic for which is shown in Figure 31, and the board layout is shown in Figure 32 and Figure 33. It can be configured for a wide variety of experiments. The board is factory set for photoconductive mode with a buffer gain of unity, providing a slope of 10 mV/dB and an intercept of 100 pA. By substituting resistor and capacitor values, all of the application circuits presented in this data sheet can be evaluated. The system is completed by the final buffer amplifier, which is an uncommitted op amp with a rail-to-rail output capability, a 10 MHz bandwidth, and good load driving capabilities. The buffer can be used to implement multipole low-pass filters for noise reduction. The buffer also facilitates modification of the output scaling and the intercept point using simple resistor divider networks and the 2 V output provided by the VREF pin. SHIELDS AND GUARDS Reducing errors from external sources in a current sensing circuit requires a different approach then the voltage sensing input of the typical high impedance op-amp circuit. Leakage can be a significant source of error for highly sensitive log amps, especially at the low end of their range. For example, a 1 GΩ leakage path to ground from the INPT input with a VSUM set to the default 0.5 V generates a 0.5 nA offset. The ADL5303 evaluation board makes extensive use of guards to reduce the effects of leakage at low input levels. It is important to carefully handle and clean the ADL5303 evaluation board to prevent contaminants from handling or improper washing of the PCB causing leakage currents. Circuit board designs for the ADL5303 must connect the EPAD to the VSUM pins to provide a continuous guard around the sensitive INPT pin to reduce the influence of surface contaminants. A common mistake for those unfamiliar with low level current sensing is to attach a high impedance scope probe or meter to measure the input for debug. This can cause significant error, as the typical 1M ~ 100 MΩ impedance of these probes sources/ sinks current from the input, depending on their bias. In instrumentation applications where measurements <1 nA are required, the use of triaxial cables and connectors is common to reduce leakage through the insulating dielectric by carrying a continuous guard from current source to sensing circuit on the intermediate conductor. This type of guarding circuit is differ- ent from a conventional electrostatic shield used in voltage sensing applications. An electrostatic shield relies on low impedance and the ability to flow current freely to minimize voltage induced on the shield that can capacitively couple into a high impedance input. A guard is actively driven to the same voltage as the current carrying center conductor eliminating leakage through the dielectric between the center conductor and the guard. The guard does not flow current other than the leakage from the guard to the outer shield. The guard is usually connected to a single end of the cable only because any signifi- cant current flow through the guard can couple inductively to the center conductor. Using the ADL5303 evaluation board, the guard can be driven either from the guard of an external current source or from the internal VSUM bias of the ADL5303. The ADL5303 evaluation board can bias the shield of a coaxial cable connected to the INPT input to the nominal VSUM voltage with Switch S1 but this requires careful consideration of the environment on the other side of the cable. For example if the ADL5303 evaluation board is configured for VSUM = 0.5 V connecting the other end of the INPT coaxial cable to an instrument with a ground referenced shield pulls VSUM to ground and collapses the input stage of the ADL5303. Floating the current source end of the shield provides a low leakage guard but a separate return path for the signal current must then be provided. If cable dielectric leakage is not a concern, the INPT can be connected directly to a coaxial cable with the shield providing a signal ground. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |