3 / 16 page ![]() K2CM 3 ■ Characteristics Note: This means that no malfunction occurs with the open-phase element, but the operating value of the overload element may vary. Variation due to temperature fluctuation At 20 ±20 °C Overcurrent: ±5% of operating value, ±10% of operating time Open-phase: ±10% of operating value, ±10% of operating time Reverse-phase: ±10% of operating value, ±10% of operating time At 20 ±30 °C Overcurrent: ±10% of operating value, ±20% of operating time Open-phase: ±20% of operating value, ±20% of operating time Reverse-phase: ±20% of operating value, ±20% of operating time Variation due to voltage fluctuation At 85% to 110% of rated voltage Overcurrent: ±5% of operating value, ±10% of operating time Open-phase: ±5% of operating value, ±10% of operating time Reverse-phase: ±5% of operating value, ±10% of operating time Variation due to frequency fluctuation At 95% to 105% of rated frequency Insulation resistance 10 M Ω min. (between current-carrying terminals and mounting panel) 5 M Ω min. (between current-carrying terminals and between contact poles) Dielectric strength 2,500 VAC (between current-carrying terminals and mounting panel and between current-carrying terminals) 1,000 VAC (between contact poles) Permissible impulse voltage Current reverse-phase detection models: 6,000 V (between current-carrying terminals and mounting panel) 4,500 V (between current-carrying terminals and between control power supply terminals) Waveform: 1.2/50 µs Voltage reverse-phase detection models: 4,500 V (between current-carrying terminals and mounting panel) Waveform: 1.2/50 µs Overcurrent strength of main circuit No abnormality develops when 20 times the set current value is applied for 2 s, 2 times with a 1- minute interval. Overvoltage strength of control power supply circuit No abnormality develops when 1.15 times the relay’s rated voltage is applied once for 3 hours. Variation due to waveform distortion No malfunction occurs when pulse containing 100% of the 2nd to 9th harmonics is applied (open- phase switch set to “Low”). (See note.) Vibration Malfunction: 10 to 55 Hz, 0.3-mm double amplitude (in X, Y, and Z directions for 10 minutes each) Destruction: 10 to 25 Hz, 2-mm double amplitude (in X, Y, and Z directions for 2 hours each) Shock Malfunction: 98 m/s2 (approx. 10 G) in X, Y, and Z directions Destruction: 294 m/s2 (approx. 30 G) in X, Y, and Z directions Test current (reference only) Operating time Set time value Setting characteristics of operating time Approx. ±30% of the maximum setting value Service life Electrical: 10,000 operations Ambient temperature Operating: −10 to 60 °C (with no icing) Storage: −25 to 65 °C Humidity 35% to 85% Altitude 2,000 m max. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |