6 / 16 page ![]() K2CM 6 Output Circuits ■ Internal Circuit and Operation Description 1) Overcurrent Circuit Overcurrent Detecting Circuit This circuit detects when the current reaches the overcurrent operat- ing level (115% of the set current value). Time Setting Circuit (Inverse Type) This circuit performs time setting using the VR (variable resistor) for the operating time setting and obtains inverse-type characteristics using an RC time-limiting circuit. The operating time can be set within a range from 2 to 10 s or 8 to 40 s by operating the setting switch using a VR. The VR covers a time range 5 times the standard range. Start-up Detecting Circuit (Instantaneous Type) Instantaneous-type models output a trip signal instantaneously when the motor current exceeds the overcurrent operating value (115% of the set current value). At the start of motor operation, a starting cur- rent several times the rated current flows and so to prevent the motor circuit being tripped by the starting current, instantaneous operation is not enabled until a fixed time tc has elapsed, as shown in the fig- ure. Instantaneous operation starts after tc has elapsed. Motor start- ing time “to” varies, depending on motor type, within a range from several seconds to several tens of seconds. There are even slight dif- ferences in starting time between the same type of motors and so be sure to set tc so that to to<tc is satisfied. If to>tc, the motor circuit will be tripped after tc has elapsed. The fixed time limit tc at the start of motor operation is called “lock time”. The start-up detecting circuit detects the starting operation level (30% max. of the set current time). Starting Time Setting Circuit (Instantaneous Type) This circuit performs time setting using the VR for setting the start-up lock time and obtains fixed time-limit characteristics using an RC time-limiting circuit. Operation at start-up is shown in the figure below. After the motor turns ON at point A, the motor’s starting current exceeds the start-up operating value and so the RC time-limiting circuit starts charging. If, for example, the motor current descends below the start-up operat- ing value (30% max. of the set current value) at point B before the start-up lock time, tc, has elapsed, the RC time-limiting circuit is reset immediately and when the motor current rises above the start-up operating value again at point C, the RC time-limiting circuit starts charging again. After the start-up lock time has elapsed (at point D), instantaneous operation is enabled. At the start of operation, the motor current is at its peak immediately after operation starts. It then lowers and settles at the rated current. The peak current is about 5 to 6 times the rated current and takes from several seconds to several tens of seconds to settle to the rated current. This time varies largely depending on type of motor and the nature of motor load (wt). There- fore, it is necessary to obtain the motor’s starting time for operation with the load and to set a start-up lock time that allows for a margin of error. Do not set an unnecessarily long start-up lock time. If the start- up lock time is too long and an accident due to overcurrent occurs at the start of operation, the trip signal will not be output until the start- up lock time has elapsed, possibly resulting in motor burnout. With instantaneous-type models, the circuit section enclosed by is configured as shown below. S1 S2 A RS T Test button Reset button To each circuit X Overcurrent indicator Open-phase indicator Reverse- phase indicator LED LED LED X/ b2 X/ a1 C2 C1 1 b2 a1 To OR circuit To each circuit To each circuit U V W Instantaneous Type B C Voltage Reverse-phase Detection Models 2 3 M Voltage circuit for test With the voltage reverse-phase detection models, the circuit section enclosed by in the diagram on the left is configured as shown below. The circuit section enclosed by is not used. A C B Inverse and Instantaneous Types As shown on the right, the K2CM detects abnormalities in motor M by checking its line current. The motor’s current signal is detected by the current transformer and is processed separately for each phase and input to the respec- tive circuits. In each circuit, par- allel judgement of failure such as overcurrent, open-phase, or reverse-phase (see note) is made based on the input signals. If a failure is detected in a circuit, the circuit’s output is input to the indication circuit to illuminate the corresponding LED indicator and also input to the relay drive cir- cuit to drive relay X, resulting in a trip signal to be externally output from it. The three major circuits are described below. Note: Applies to current reverse- phase detection models only. to tc Start Motor current Operating mode Instantaneous operation enabled Fixed time-limit operation Overcurrent operating value to: Motor's starting time tc: Lock time at start of operation Start Start tc tc tc Start Trip Output Operation mode Motor current tc: Start-up lock time *: Fixed time-limit operation A B C D E F H G Overcurrent operating value Start-up operating value **: Instantaneous operation enabled * * * ** ** |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |