| 数据搜索系统,热门电子元器件搜索 |
|
PBV-R005-0.5 数据表(PDF) 5 Page - AVAGO TECHNOLOGIES LIMITED |
|
|
|||||||||||||||||||||||||||||
PBV-R005-0.5 数据表(HTML) 5 Page - AVAGO TECHNOLOGIES LIMITED |
|
5 / 18 page ![]() 5 Table 3. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics [1] Description Symbol Value Units Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms for rated mains voltage ≤ 450 V rms for rated mains voltage ≤ 600 Vrms I-IV I-IV I-IV I-IV Climatic Classification 55/105/21 Pollution Degree (DIN VDE 0110/1.89) 2 Maximum Working Insulation Voltage VIORM 891 Vpeak Input to Output Test Voltage, Method b VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial Discharge < 5 pC VPR 1671 Vpeak Input to Output Test Voltage, Method a VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial Discharge < 5 pC VPR 1426 Vpeak Highest Allowable Overvoltage (Transient Overvoltage, tini = 60 sec) VIOTM 8000 Vpeak Safety-limiting values (Maximum values allowed in the event of a failure) Case Temperature Input Current [2] Output Power [2] TS IS,INPUT PS,OUTPUT 175 400 600 °C mA mW Insulation Resistance at TS, VIO = 500 V RS ≥ 109 Ω Notes: 1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the application. 2. Safety-limiting parameters are dependent on ambient temperature. The Input Current, IS,INPUT, derates linearly above 25° C free-air temperature at a rate of 2.67 mA/°C; the Output Power, PS,OUTPUT, derates linearly above 25° C free-air temperature at a rate of 4 mW/°C. Table 4. Insulation and Safety Related Specifications Parameter Symbol Value Units Conditions Minimum External Air Gap (External Clearance) L(101) 7.4 mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (External Creepage) L(102) 8.0 mm Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Plastic Gap (Internal Clearance) 0.5 mm Through insulation distance, conductor to conductor, usually the direct distance between the photoemitter and photodetector inside the optocoupler cavity Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1 Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |