9 / 12 page ![]() Datasheet SHT25 www.sensirion.com Version 0.91 – October 2010 9/12 5.5 Soft Reset This command (see Table 6) is used for rebooting the sensor system without switching the power off and on again. Upon reception of this command, the sensor system reinitializes and starts operation according to the default settings – with the exception of the heater bit in the user register (see Sect. 5.6). The soft reset takes less than 15ms. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 S 1 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 P I2C address + write Soft Reset Figure 17 Soft Reset – grey blocks are controlled by SHT2x. 5.6 User Register The content of User Register is described in Table 8. Please note that reserved bits must not be changed and default values of respective reserved bits may change over time without prior notice. Therefore, for any writing to the User Register, default values of reserved bits must be read first. Thereafter, the full User Register string is composed of respective default values of reserved bits and the remainder of accessible bits optionally with default or non-default values. Bit # Bits Description / Coding Default 7, 0 2 Measurement resolution RH T ‘00’ 12 bit 14 bit ‘01’ 8 bit 12 bit ‘10’ 10 bit 13 bit ‘11’ 11 bit 11 bit ‘00’ 6 1 Status: End of battery15 ‘0’: VDD > 2.25V ‘1’: VDD < 2.25V ‘0’ 3, 4, 5 3 Reserved 2 1 Enable on-chip heater ‘0’ 1 1 Disable OTP Reload ‘1’ Table 8 User Register. Cut-off value for End of Battery signal may vary by ±0.05V. Reserved bits must not be changed. “OTP reload” = ‘0’ loads default settings after each time a measurement command is issued. The end of battery alert is activated when the battery power falls below 2.25V. The heater is intended to be used for functionality diagnosis – relative humidity drops upon rising temperature. The heater consumes about 5.5mW and provides a temperature increase of about 0.5 – 1.5°C. OTP Reload is a safety feature and loads the entire OTP settings to the register, with the exception of the heater bit, 15 This status bit is updated after each measurement before every measurement. This feature is disabled per default and is not recommended for use. Please use Soft Reset instead – it contains OTP Reload. An example for I2C communication reading and writing the User Register is given in Figure 18. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 S 1 0 0 0 0 0 0 0 1 1 1 0 0 1 1 1 I2C address + write Read Register 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 S 1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 I2C address + read Register content 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 S 1 0 0 0 0 0 0 0 1 1 1 0 0 1 1 0 I2C address + write Write Register 55 56 57 58 59 60 61 62 63 0 0 0 0 0 0 1 1 P Register content to be written Figure 18 Read and write register sequence – grey blocks are controlled by SHT2x. In this example, the resolution is set to 8bit / 12bit. 5.7 CRC Checksum CRC8 is a well known standard checksum concept. For implementation please refer to public sources such as Wikipedia. 5.8 Serial Number SHT25 provides an electronic identification code. For instructions on how to read the identification code please refer to the Application Note “Electronic Identification Code” – to be downloaded from the web page www.sensirion.com/sht25. 6 Conversion of Signal Output Default resolution is set to 12 bit relative humidity and 14 bit temperature reading. Measured data are transferred in two byte packages, i.e. in frames of 8 bit length where the most significant bit (MSB) is transferred first (left aligned). Each byte is followed by an acknowledge bit. The two status bits, the last bits of LSB, must be set to ‘0’ before calculating physical values. In the example of Figure 15 and Figure 16, the transferred 16 bit relative humidity data is ‘0110’0011’0101’0000’ = 25424. 6.1 Relative Humidity Conversion With the relative humidity signal output SRH the relative humidity RH is obtained by the following formula (result in %RH), no matter which resolution is chosen: |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |