| 数据搜索系统,热门电子元器件搜索 |
|
JS28F128P30TF75A 数据表(PDF) 76 Page - Micron Technology |
|
|
|||||||||||||||||||||||||||||
JS28F128P30TF75A 数据表(HTML) 76 Page - Micron Technology |
|
76 / 90 page ![]() P30-65nm SBC Datasheet Apr 2010 76 Order Number: 208033-02 Figure 35: Buffer Program Flowchart Start Get Next Target Address Issue Write to Buffer Command E8h Block Address Read Status Register Block Address (note 7) Is WSM Ready ? SR. 7= 1 = Yes Device Supports Buffer Writes? Set Timeout or Loop Counter Timeout or Count Expired ? Write Confirm D0h Block Address Another Buffered Programming? Yes No No Write Buffer Data Start Address X =0 Yes 0 = No No Yes Use Single Word Programming Abort Bufferred Program? No X =N ? Write Buffer Data Address within buffer range X = X +1 Write to another Block Address Buffered Program Aborted No Yes Yes Write Word Count Block Address Notes: 1. Word count values on DQ 0-DQ15 are loaded into the Count register. Count ranges for this device are N=0000h to 00FFh. 2. The device outputs the Status Register when read. 3. Write Buffer contents will be programmed at the device start address or destination flash address . 4. Align the start address on a Write Buffer boundary for maximum programming performance (i.e., A8-A1 of the start address =0). 5. The device aborts the Buffered Program command if the current address is outside the original block address . 6. The Status register indicates an “improper command Sequence” if the Buffered Program command is aborted. Follow this with a Clear Status Register command . 7. The device defaults to output SR data after the Buffered Programming Setup Command (E8h) is issued . CE# or OE# must be be toggled to update Status Register . Don’t issue the Read SR command (70h), which would be interpreted by the internal state machine as Buffer Word Count. 8. Full status check can be done after all erase and write sequences complete . Write FFh after the last operation to reset the device to read array mode. . . . Bus Operation Standby Read Command Write Write to Buffer Read (Note 7) Standby Comments Check SR.7 1 = WSM Ready 0 = WSM Busy Status register Data CE# and OE# low updates SR Addr = Block Address Data =E8H Addr = Block Address SR. 7 = Valid Addr = Block Address Check SR.7 1 = Device WSM is Busy 0 = Device WSM is Ready Write Program Confirm Data =D0H Addr = Block Address Write ( Notes1, 2) Data =N- 1 = Word Count N = 0 corresponds to count=1 Addr = Block Address Write ( Notes3, 4) Data = Write Buffer Data Addr =Address within buffer range Write ( Notes5, 6) Data = Write Buffer Data Addr = Block Address Suspend Program Loop Read Status Register SR. 7=? Full Status Check if Desired Program Complete Suspend Program 1 0 No Yes Clear Status Register 50h Address within Device Yes |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |