| 数据搜索系统,热门电子元器件搜索 |
|
E5CS-R1KJX-F 数据表(PDF) 7 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
E5CS-R1KJX-F 数据表(HTML) 7 Page - Omron Electronics LLC |
|
7 / 10 page ![]() Temperature Controller E5CS--X A--152 Installation J Mounting All E5CS-X models conform to DIN 43700 standard. Recom- mended panel thickness is 1 to 4 mm (0.04 to 0.16 in). Insert the temperature controller, back end first, into the panel cutout. Mount the adapter (Y92F-30) supplied with each unit by pushing it forward from the back of the temperature controller. Push the adapter as close as possible to the front panel of the temperature controller to eliminate the gap between them. Then, secure the adapter with screws as shown. Removal Loosen the screws on the adapter and push the hook open to remove the adapter. Hook Screw J Connections Connection Examples Use M3.5 solderless terminals with the temperature controller’s M3.5 self-rising pressure plate screws. For solder-dipped leads, strip the lead wire 6 to 12 mm (0.24 to 0.47 in) and carefully insert the wire tip. Do not tighten the termi- nal screw with excessive force. 7.5 (0.29) 7.3 (0.29) max. 19 (0.75) 6to12 (0.24to0.47) Precautions J Environment Do not install the temperature controller in a location where there is a lot of dust or corrosive gases. Also avoid a location where the temperature controller is subjected to heavy vibration, shock, splashes of water or oil, and high temperatures. Separate the temperature controller from equipment that generates strong, high-frequency electrical noise such as welding equipment. Sensor Input Connections The lead wires connecting the platinum RTD to the temperature controller must be separated from the power lines an the load lines, wherever possible, to prevent them from being inducted by electrical noise. Use the specified compensating conductors for the thermocouple input type temperature controllers. Use lead wires having a small resistance for the platinum RTD type temperature controllers. Sequence Circuit Several seconds are required until the relay is turned ON after the power has been applied to the temperature controller. Be sure to take this time lag into consideration when designing a sequence circuit which incorporates this temperature controller. J Recalibration The E5CS-X temperature controller can be recalibrated by a factory-authorized repair service. Contact Omron for the location near you. Unauthorized recalibration of the controller will void the warranty and may lead to erratic operation. |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |